Improving self-calibration.

نویسندگان

  • Torsten A Enßlin
  • Henrik Junklewitz
  • Lars Winderling
  • Maksim Greiner
  • Marco Selig
چکیده

Response calibration is the process of inferring how much the measured data depend on the signal one is interested in. It is essential for any quantitative signal estimation on the basis of the data. Here, we investigate self-calibration methods for linear signal measurements and linear dependence of the response on the calibration parameters. The common practice is to augment an external calibration solution using a known reference signal with an internal calibration on the unknown measurement signal itself. Contemporary self-calibration schemes try to find a self-consistent solution for signal and calibration by exploiting redundancies in the measurements. This can be understood in terms of maximizing the joint probability of signal and calibration. However, the full uncertainty structure of this joint probability around its maximum is thereby not taken into account by these schemes. Therefore, better schemes, in sense of minimal square error, can be designed by accounting for asymmetries in the uncertainty of signal and calibration. We argue that at least a systematic correction of the common self-calibration scheme should be applied in many measurement situations in order to properly treat uncertainties of the signal on which one calibrates. Otherwise, the calibration solutions suffer from a systematic bias, which consequently distorts the signal reconstruction. Furthermore, we argue that nonparametric, signal-to-noise filtered calibration should provide more accurate reconstructions than the common bin averages and provide a new, improved self-calibration scheme. We illustrate our findings with a simplistic numerical example.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-Calibration of Cluster Dark Energy Studies: Counts in Cells

Cluster number counts can constrain the properties of dark energy if and only if the evolution in the relationship between observable quantities and the cluster mass can be calibrated. Next generation surveys with ∼ 10 clusters will have sufficient statistics to enable some degree of self-calibration. The excess variance of counts due to the clustering of clusters provides such an opportunity a...

متن کامل

Digital Offset Calibration of an OPAMP Towards Improving Static Parameters of 90 nm CMOS DAC

In this article, an on-chip self-calibrated 8bit R-2R digital-to-analog converter (DAC) based on digitally compensated input offset of the operational amplifier (OPAMP) is presented. To improve the overall DAC performance, a digital offset cancellation method was used to compensate deviations in the input offset voltage of the OPAMP caused by process variations. The whole DAC as well as offset ...

متن کامل

Comparative Geometric Tests of Industrial and Scientific Ccd Cameras Using Plumb Line and Test Range Calibrations

Small format, medium resolution CCD cameras are at present widely used for industrial metrology applications. Large format, high resolution CCD cameras are principally used for scientific applications, but are slowly infiltrating photogrammetry and dramatically improving the object space accuracy achievable by close range measurement. The calibration of all types of CCD cameras is necessary in ...

متن کامل

IMU-Based Online Kinematic Calibration of Robot Manipulator

Robot calibration is a useful diagnostic method for improving the positioning accuracy in robot production and maintenance. An online robot self-calibration method based on inertial measurement unit (IMU) is presented in this paper. The method requires that the IMU is rigidly attached to the robot manipulator, which makes it possible to obtain the orientation of the manipulator with the orienta...

متن کامل

On the Self-calibration of Long Focal Length Lenses

One of the practical impediments to the adoption of long focal length cameras in close-range photogrammetry is the difficulty in network exterior orientation and self-calibration that can be encountered with the collinearity equation model when the camera field of view is smaller than around 10. This paper reports on an investigation that examined two avenues for improving the selfcalibration o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review. E, Statistical, nonlinear, and soft matter physics

دوره 90 4  شماره 

صفحات  -

تاریخ انتشار 2014