Comparison of Semi-Automated and Manual Measurements of Carotid Intima-Media Thickening

نویسندگان

  • Oscar Mac Ananey
  • Greg Mellotte
  • Vincent Maher
چکیده

Carotid intima-media thickening (CIMT) is a marker of both arteriosclerotic and atherosclerotic risks. Technological advances have semiautomated CIMT image acquisition and quantification. Studies comparing manual and automated methods have yielded conflicting results possibly due to plaque inclusion in measurements. Low atherosclerotic risk subjects (n = 126) were recruited to minimise the effect of focal atherosclerotic lesions on CIMT variability. CIMT was assessed by high-resolution B-mode ultrasound (Philips HDX7E, Phillips, UK) images of the common carotid artery using both manual and semiautomated methods (QLAB, Phillips, UK). Intraclass correlation coefficient (ICC) and the mean differences of paired measurements (Bland-Altman method) were used to compare both methodologies. The ICC of manual (0.547 ± 0.095 mm) and automated (0.524 ± 0.068 mm) methods was R = 0.74 and an absolute mean bias ± SD of 0.023 ± 0.052 mm was observed. Interobserver and intraobserver ICC were greater for automated (R = 0.94 and 0.99) compared to manual (R = 0.72 and 0.88) methods. Although not considered to be clinically significant, manual measurements yielded higher values compared to automated measurements. Automated measurements were more reproducible and showed lower interobserver variation compared to manual measurements. These results offer important considerations for large epidemiological studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between automated and manual measurements of carotid intima-media thickness in clinical practice

BACKGROUND AND AIM The measurement of carotid intima-media thickness (cIMT) has been used as a marker of arterial wall disease. Manual measurements have been performed in most epidemiological studies, but, due to the introduction of new technologies, automated software has been increasingly used. This study aimed to compare manual versus automated cIMT measurements in common carotid (CC), bifur...

متن کامل

بررسی نقش کبد چرب بر خطر بیماری‌های قلبی- عروقی از طریق اندازه‌گیری ضخامت انتیمامدیای شریان کاروتید

Background and Aim: A lot of studies  is done about various components of the metabolic syndrome in association with non-alcoholic fatty liver due to increasing carotid intima media thickness as a risk factor of cardiovascular diseases. But few studies have been done on the role of non-alcoholic fatty liver as an independent risk factor for carotid intima media thickening. The present stud...

متن کامل

Comparison of the Intima-media Thickness of Carotid Artery in Children with Diabetes Type One and Control Group Using Ultrasound

Background & Aims: Diabetes is a very important factor for stroke due to blocked blood vessels. It can involve systemic and cerebrovascular arteries at the same time via microangiopathy and macroangiopathy. This project aimed to compare the intima-media thickness of carotid artery in children with diabetes type and the control group. Methods: In this case-control study, 50 children with the age...

متن کامل

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

Automated measurement of intima-media thickness of carotid arteries in ultrasonography by computer software.

PURPOSE Intima-media thickness (IMT) has been proposed to be a morphological criterion of atherosclerosis. The purpose of this study was to investigate the interobserver variability of manual and also of computer software measurements of IMT. MATERIALS AND METHODS High-resolution common carotid artery (CCA) images of 88 patients that have been obtained by a linear broadband L5-12 MHz transduc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014