Development of HTS Transformers and a 10 kVA HTS Transformer Prototype Design
نویسندگان
چکیده
⎯With the improvement of high temperature superconductor (HTS) practical performance, research and development concerning the applications of HTS transformers have been progressed actively worldwide. This paper provides a comprehensive summary on various HTS transformers, and studies the design of a single-phase 10 kVA (220V/24V) HTS transformer prototype to verify HTS for practical transformer applications. Index Terms⎯HTS, HTS power transformer, HTS traction transformer, HTS windings.
منابع مشابه
Design and Simulation of a 100 kVA Intelligent Universal Transformer Enjoying the Voltage Ratio of 20kv:380v
In order to reduce the volume and size of distribution power transformer, precise and extended controlling of transformer output, the conventional transformers are replaced by intelligent universal transformers (IUTs). In this paper, an IUT, typical of Iran national grid, with the voltage ratio of 20kV:380 V is designed and simulated. Regarding the IUT implementation, a cascaded H-bridge invert...
متن کاملA Digital Flux Injector for NMR
It has been known for some time that high-temperature superconductors (HTS) are critical for the construction of NMR magnets generating 1 GHz and above. Such systems generally require an HTS insert to be placed in the inner high-field region of a low temperature superconducting (LTS) magnet. Among the problems in the presently available HTS technology are splice resistance and index dissipation...
متن کاملOptimization of an HTS Induction/Synchronous Motor According to Changing of HTS Tapes Critical Current by Analytical Hierarchy Process
This paper represents the performance of a squirrel-cage High Temperature Superconducting Induction/ Synchronous Motor (HTS-ISM) based on nonlinear electrical equivalent circuit. The structure of the HTS-ISM is the same as that of the squirrel-cage type induction machine, and the secondary windings are fabricated by the use of the HTS wires. It has already been shown that based on the experimen...
متن کاملHTS dc-SQUID flip-chip magnetometers and gradiometers
Biomagnetic research requires measuring systems with the utmost sensitivity to magnetic fields. The strongest challenge is fMEG measurements with a typical (20 – 200) fT peak-to-peak signal magnitude. An average R-wave magnitude of a fMCG signal is ∼2 pT. Measuring in a frequency bandwidth of about 100 Hz with a signal-to-noise ratio of ∼10 demands a system noise for fMCG measurements ∼20 fT/√H...
متن کاملReduction of Radio Frequency Interference to HTS-dc-SQUID by Adding a Cooled Transformer
Effect of an addition of a cooled step-up transformer to a flux locked loop (FLL) circuit was studied to reduce indirect rf interference to HTS-dc-SQUID. First, we demonstrated that a noise level of an HTS-dcSQUID system using the FLL circuit with single room-temperature transformer could be easily degraded by radiation of rf electromagnetic wave to cables in the FLL circuit. It is thought that...
متن کامل