Modified atomic force microscopy cantilever design to facilitate access of higher modes of oscillation
نویسندگان
چکیده
The detection of higher modes of oscillation in atomic force microscopy can provide additional information on sample properties. However, the limited bandwidth of the photodiode in the beam deflection detection technique often limits the detectable frequency range. We present a novel cantilever design, which allows lowering the frequency of higher modes of oscillation, maintaining the frequency of the fundamental resonance. Simulations by finite element methods show that the ratio between the second mode and the fundamental resonance frequency can be adjusted between 2 and 10, compared to 6.3 for the regular rectangular cantilever design. Even stronger changes are observed for the third oscillation mode, corresponding to a torsional cantilever oscillation. Cantilevers with modified geometry were fabricated using silicon micromachining processes and subsequently tested, confirming the results from the simulation. © 2006 American Institute of Physics. DOI: 10.1063/1.2219738
منابع مشابه
Sensitivity analysis of a caliper formed atomic force microscope cantilever based on a modified couple stress theory
A relationship based on the modified couple stress theory is developed to investigate the flexural sensitivity of an atomic force microscope (AFM) with assembled cantilever probe (ACP). This ACP comprises a horizontal cantilever, two vertical extensions and two tips located at the free ends of the extensions which form a caliper. An approximate solution to the flexural vibration problem is obta...
متن کاملSensitivity analysis of a caliper formed atomic force microscope cantilever based on a modified couple stress theory
A relationship based on the modified couple stress theory is developed to investigate the flexural sensitivity of an atomic force microscope (AFM) with assembled cantilever probe (ACP). This ACP comprises a horizontal cantilever, two vertical extensions and two tips located at the free ends of the extensions which form a caliper. An approximate solution to the flexural vibration problem is obta...
متن کاملDynamic modeling and nonlinear vibration simulation of piezoelectric micro-beam in self sensing mode of atomic force microscope
Nowadays, atomic force microscope is considered as a useful tool in the determination of intermolecular forces and surface topography with the resolution of nanometers. In this kind of microscope, micro cantilever is considered as the heart of the microscope and is used as a measuring tool. This paper is aimed towards investigating the behavior of a piezoelectric micro cantilever with a triang...
متن کاملAccurate formulas for interaction force and energy in frequency modulation force spectroscopy
Frequency modulation atomic force microscopy utilizes the change in resonant frequency of a cantilever to detect variations in the interaction force between cantilever tip and sample. While a simple relation exists enabling the frequency shift to be determined for a given force law, the required complementary inverse relation does not exist for arbitrary oscillation amplitudes of the cantilever...
متن کاملSensitivity Analysis of Frequency Response of Atomic Force Microscopy in Liquid Environment on Cantilever's Geometrical Parameters
In this paper, the non-linear dynamic response of rectangular atomic force microscopy in tapping mode is considered. The effect of cantilever’s geometrical parameters (e.g., cantilever length, width, thickness, tip length and the angle between the cantilever and the sample's surface in liquid environment has been studied by taking into account the interaction forces. Results indicate that the r...