Valve replacement for aortic stenosis in patients with poor left ventricular function: comparison of early changes with stented and stentless valves.

نویسندگان

  • J Collinson
  • M Henein
  • M Flather
  • J R Pepper
  • D G Gibson
چکیده

BACKGROUND Long-standing aortic stenosis causes significant left ventricular (LV) dysfunction, which may progress irreversibly. In many cases, LV function can be salvaged by aortic valve surgery, although debate exists regarding the best valve prosthesis to use. METHODS AND RESULTS We studied 33 patients retrospectively who had significant aortic stenosis and impaired LV systolic function, as assessed by transthoracic Doppler echocardiography. Patients were assessed preoperatively and before discharge from the hospital. A total of 20 patients received a stentless (homograft or Toronto) valve, and 13, a stented valve. No patient had significant aortic regurgitation or other valvular disease. Preoperatively, fractional shortening was 18.8+/-5.5% in the stentless group and 18.6+/-3.8% in the stented group. Postoperatively, it was 25.6+/-6.9% (P<0.001 compared with baseline) and 17.0+/-2.8%, respectively (P<0.001 compared with stentless group). Fractional shortening improved because of a reduction in LV end-systolic and end-diastolic dimensions in the stentless group. Systolic long axis function at the LV free wall also recovered, with an increase in systolic excursion and both peak shortening and lengthening rates. No change was noted in mitral valve Doppler patterns. CONCLUSIONS Patients who received a stentless valve demonstrated a significantly greater early improvement in LV systolic function compared with those who received a stented valve.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves

BACKGROUND Full-root aortic valve replacement with stentless xenografts has potentially superior hemodynamic performance compared to stented valves. However, a number of cardiac surgeons are reluctant to transform a classical stented aortic valve replacement into a technically more demanding full-root stentless aortic valve replacement. Here we describe our technique of full-root stentless aort...

متن کامل

Haemodynamics and left ventricular mass regression: a comparison of the stentless, stented and mechanical aortic valve replacement.

OBJECTIVE Our objective was to compare the degree of change in hemodynamics and left ventricular mass (LVM) regression after aortic valve replacement (AVR) with stentless, stented and mechanical valves. METHODS Patients greater than 59 years of age had AVR for aortic stenosis with the stentless xenograft (Cryolife-O'Brien, CLOB), stented xenograft (Carpentier-Edwards, C-E) or mechanical valve...

متن کامل

Randomized comparison of stentless versus stented valves for aortic stenosis: effects on left ventricular mass.

BACKGROUND Aortic valve replacement (AVR) is the established treatment for severe aortic stenosis. In response to the long-term results of aortic homografts, stentless porcine valves were introduced as an alternative low-resistance valve. We conducted a randomized trial comparing a stentless with a stented porcine valve in adults with severe aortic stenosis. METHODS AND RESULTS The primary ou...

متن کامل

Are stentless valves superior to modern stented valves? A prospective randomized trial.

BACKGROUND It is presumed that stentless aortic bioprostheses are hemodynamically superior to stented bioprostheses. A prospective randomized controlled trial was undertaken to compare stentless versus modern stented valves. METHODS AND RESULTS Patients with severe aortic valve stenosis (n=161) undergoing aortic valve replacement (AVR) were randomized intraoperatively to receive either the C-...

متن کامل

Performance of stentless versus stented aortic valve bioprostheses in the elderly patient: a prospective randomized trial.

OBJECTIVES Although stentless aortic bioprostheses are believed to offer improved outcomes, benefits remain unsubstantiated. The aim of our study was to compare stentless with stented bioprostheses, with regard to postoperative changes in left ventricular mass and hemodynamic performance, in the elderly patient. METHODS Forty patients with aortic stenoses, over the age of 75 years, were rando...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 100 19 Suppl  شماره 

صفحات  -

تاریخ انتشار 1999