One-Year Safet of Intracoronary Ultrasonic Imaging Evaluation With Serial Quantitative Angiography

نویسندگان

  • Fausto J. Pinto
  • Edwin L. Alderman
چکیده

Background. Intracoronary ultrasound (ICUS) has the ability to quantitatively evaluate vessel wall morphology and is well suited for serial studies of coronary artery disease regression and progression. However, the potential risk for catheter-induced endothelial damage and accelerated atherosclerosis in instrumented vessels is a concern. The acute effects as well as the 1-year safety of ICUS regarding its impact on the atherosclerotic process were assessed. Methods and Results. The acute studies include 240 intracoronary studies performed in 170 cardiac transplant recipients. Patients were systematically heparinized. Only vessels >2 mm in diameter were visualized. Coronary arteries of 38 patients were measured by quantitative coronary angiography in matched angiograms at an interval of 1 year after the initial ICUS examination was performed to assess long-term effects. The angiographic measurements in the previously instrumented and noninstrumented vessels were compared. Forty-nine vessels that had been imaged (IM) in these 38 patients with a SF ICUS catheter were compared with 61 vessels not previously imaged (NIM) in the same patients. Absolute and percentage change in angiographically measured mean vessel diameters in the ICUS imaged and nonimaged segments were compared. Despite pretreatment with nitroglycerin, 20 patients (8.3%) had angiographically evident coronary spasm. In all cases, this was reversed by giving nitroglycerin. One year after the original imaging study, no difference was noted between imaged and nonimaged vessels in change in absolute vessel diameter (IM, -0.11±0.28 mm vs NIM, -0.07±0.22 mm; P=.49) or in percentage change in diameter (IM, -5±11% vs NIM, -3+7%; P=.32). Conclusions. Intracoronary ultrasound in cardiac transplant recipients was associated with no clinical morbidity and a low incidence of vessel spasm in large and medium-size coronary arteries. It does not accelerate progression ofangiographically quantifiable coronary artery disease. This study suggests that ICUS can be safely used even in coronary arteries not undergoing interventions. (Citruaion. 1993;88[part 1]: 1709-1714.)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibilit of Serial Intracoronary Ultrasound Imaging for Assessment of Progression of Intimal Proliferation in Cardiac Transplant Recipients

Background Serial quantitative coronary angiography is used to assess progression of coronary disease; however, pathology studies have demonstrated angiographic insensitivity for determining atheroma. Intracoronary ultrasound (ICUS) can define and measure the components of the arterial wall and offers the potential for precise quantitative assessment of disease progression on serial examination...

متن کامل

Feasibility of serial intracoronary ultrasound imaging for assessment of progression of intimal proliferation in cardiac transplant recipients.

BACKGROUND Serial quantitative coronary angiography is used to assess progression of coronary disease; however, pathology studies have demonstrated angiographic insensitivity for determining atheroma. Intracoronary ultrasound (ICUS) can define and measure the components of the arterial wall and offers the potential for precise quantitative assessment of disease progression on serial examination...

متن کامل

Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging.

AIMS To assess the value of videodensitometric quantification of the coronary lumen after angioplasty by comparison to two other techniques of coronary artery lumen quantification. METHODS AND RESULTS Videodensitometric quantitative angiography, edge detection quantitative angiography and 30 MHz intracoronary ultrasound imaging were performed after successful balloon angioplasty in 161 patien...

متن کامل

First serial assessment at 6 months and 2 years of the second generation of absorb everolimus-eluting bioresorbable vascular scaffold: a multi-imaging modality study.

BACKGROUND Nonserial observations have shown this bioresorbable scaffold to have no signs of area reduction at 6 months and recovery of vasomotion at 1 year. Serial observations at 6 months and 2 years have to confirm the absence of late restenosis or unfavorable imaging outcomes. METHODS AND RESULTS The ABSORB trial is a multicenter single-arm trial assessing the safety and performance of an...

متن کامل

Serial Myocardial Imaging after a Single Dose of Thallium-201

Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005