Measurement of oxygen saturation in the retina with a spectroscopic sensitive multi aperture camera.
نویسندگان
چکیده
We introduce a new multi aperture system capable of capturing six identical images of the human fundus at six different spectral bands. The system is based on a lenslet array architecture and is well suited for spectroscopy application. The multi-aperture system was interfaced with a fundus camera to acquire spectroscopic sensitive images of the retina vessel and ultimately to calculate oxygen saturation in the retina in vivo. In vitro testing showed that the system is able to accurately reconstruct curves of partially oxygenated hemoglobin. In vivo testing on healthy volunteers was conducted and yielded results of oxygen saturation similar to the one reported in the literature, with arterial SO(2) approximately 0.95 and venous SO(2) approximately 0.5.
منابع مشابه
Qualitative near-infrared vascular imaging system with tuned aperture computed tomography.
We developed a novel system for imaging and qualitatively analyzing the surface vessels using near-infrared (NIR) radiation using tuned aperture computed tomography (TACT(®)). The system consisted of a NIR-sensitive CCD camera surrounded by sixty light emitting diodes (with wavelengths alternating between 700 or 810 nm). This system produced thin NIR tomograms, under 0.5 mm in slice thickness. ...
متن کاملRetinal oximetry with a scanning laser ophthalmoscope.
PURPOSE The purpose of the study was to assess if a scanning laser ophthalmoscope (SLO), Optomap 200Tx, could be used for measurements of hemoglobin oxygen saturation in retinal blood vessels. METHODS Optomap 200Tx uses two lasers for image acquisition, 532 and 633 nm. Retinal images of healthy individuals and patients with retinal vein occlusion were analyzed with modified Oxymap Analyzer so...
متن کاملOptimization of Gate’s technique for measurement of GFR during routine renal scan [Persian]
Using Gate’s technique for GFR measurement with Gamma camera, the patient is received 5mCi of Tc-99m-DTPA. By this amount of radioactivity, good quality renal scan is not possible. This study tries to optimize Gate’s technique for GFR measurement during routine renal scan (with 10-15 mCi). Methods and materials: Scanning was performed for 60 seconds from samples of Tc-99m with activities ...
متن کاملMeasurement of oxygen saturation in small retinal vessels with adaptive optics confocal scanning laser ophthalmoscope.
We have used an adaptive optics confocal scanning laser ophthalmoscope to assess oxygen saturation in small retinal vessels. Images of the vessels with a diameter smaller than 50 μm are recorded at oxygen sensitive and isosbestic wavelengths (680 and 796 nm, respectively). The vessel optical densities (ODs) are determined by a computer algorithm. Then, OD ratios (ODRs), which are inversely prop...
متن کاملHyperspectral Computed Tomographic Imaging Spectroscopy of Vascular Oxygen Gradients in the Rabbit Retina In Vivo
Diagnosis of retinal vascular diseases depends on ophthalmoscopic findings that most often occur after severe visual loss (as in vein occlusions) or chronic changes that are irreversible (as in diabetic retinopathy). Despite recent advances, diagnostic imaging currently reveals very little about the vascular function and local oxygen delivery. One potentially useful measure of vascular function...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 16 9 شماره
صفحات -
تاریخ انتشار 2008