Human monocytoid cell lines as indicators of endotoxin: comparison with rabbit pyrogen and Limulus amoebocyte lysate assay.
نویسندگان
چکیده
The aim of this study was to develop an in vitro test system for pyrogenic substances. Three clones derived from human monocytoid cell lines, which were selected by their high sensitivity to lipopolysaccharide (LPS), were assessed for tumor necrosis factor (TNF) production. Their response to pyrogen-containing samples was compared with that in a Limulus amoebocyte lysate assay and the rabbit pyrogen test. We show here that the induction of TNF in these clones is a valid in vitro alternative to determine endotoxin in commercial preparations requiring pyrogenicity testing. Cell clones derived from Mono Mac 6 (MM6 2H8 and MM6 4B5) responded to sub-ng/ml concentrations of complete rough-strain and smooth-strain LPS, to ng/ml concentrations of diphosphoryl-lipid A, and to microgram/ml concentrations of monophosphoryl-lipid A and to detoxified LPS. Cells reacted to > or = 1 microgram/ml lipoteichoic acid by TNF production, and were relatively insensitive to toxic shock syndrome toxin-1 (TSST-1) and to muramyl dipeptide adjuvant peptide. The reaction pattern of a clone derived from THP-1 (THP-1 1G3) was in general, similar to that of the MM6 clones, except that THP-1 1G3 failed to react to diphosphoryl-lipid A. When tested on commercial samples destined for parenteral use, there was a close correlation between a sensitive Limulus amoebocyte lysate (LAL) test and the cell culture test on the one hand, and between the pyrogen test and the cell culture test on the other hand. The data suggest that this cell-based test is able to recognize pyrogens derived from gram-negative organisms in test samples with appropriate sensitivity and specificity. This test appears to be able to eliminate some of the false-positive data obtained in the LAL test.
منابع مشابه
Endotoxin Contamination of Large Volume Parenterals as Detected by Limulus Amebocyte Lysate as an Alternative to Rabbit Pyrogen Test
The possibility of replacing the rabbit pyrogen test by the Limulus Amebocyte lysate (LAL) test, as a final release test for Large Volume Parenterals (LVPs) was investigated. The sensitivity and specificity of the LAL test and rabbit pyrogen assay were studied by means of artificially contaminated parenterals. Various LVPs (mostly containing electrolytes) were spiked with 0.5 and 5 EUlml o...
متن کاملRelative potencies of four reference endotoxin standards as measured by the Limulus amoebocyte lysate and USP rabbit pyrogen tests.
Four commonly used reference endotoxin standards, Escherichia coli O113:H10:K0, E. coli O55:B5, Salmonella abortusequi, and Shigella dysenteriae were compared by the USP rabbit pyrogen and the Limulus amoebocyte lysate tests. By the rabbit pyrogen test, S. abortus equi was identified as the most potent endotoxin, followed closely by E. coli O113:H10:K0 and E. coli O55:B5.
متن کاملLimulus amoebocyte lysate assay for detection and quantitation of endotoxin in a small-volume parenteral product.
A Limulus amoebocyte lysate gel-clotting method for the determination of endotoxin in a small-volume parenteral product has been described. Sample dilution with 0.1 M potassium phosphate monobasic buffer (pH 8.0) effectively eliminated assay interference, whereas dilution with water did not. The threshold pyrogenic dose for Escherichia coli EC-2 and O127:B8 endotoxins was determined to be 1.0 n...
متن کاملEndotoxin contamination of enzyme conjugates used in enzyme-linked immunosorbent assays.
The specificity of the enzyme-linked immunosorbent assay(s) is thought to depend on the specificity of the antibody used in the assay system. Therefore, the association of broadly reactive antigens like endotoxin with enzyme conjugates or other enzyme-linked immunosorbent assay reagents has the potential of altering the specificity of reactions in the enzyme-linked immunosorbent assay. Using th...
متن کاملDetection of endotoxin in the plasma of patients with gram-negative bacterial sepsis by the Limulus amoebocyte lysate assay.
A total of 120 Limulus amoebocyte lysate (LAL) determinations were made on plasma obtained from normal, healthy human blood donors. Results demonstrated a mean endotoxin level in blood of 0.02 to 1.57 pg/ml. The amount of Escherichia coli endotoxin added to human plasma samples can be quantitated by both nephelometry and turbidimetry. Endotoxin-spiked samples were shown to be significantly diff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of immunological methods
دوره 207 2 شماره
صفحات -
تاریخ انتشار 1997