Study of Spread of Harmonics in an Electric Grid
نویسندگان
چکیده
This paper presents an algorithm for estimating the Total Harmonic Distortion (THD) in the electrical power grid nodes, which is based on a load flow analysis by frequency component. The aim of this algorithm is, on the one hand, to model the linear and non-linear loads which would be part of an electrical network and, on the other hand, to estimate the THD which would appear in the network nodes, in order to evaluate its effects and consequences, as well as to choose the best alternative for solving these problems. The proposed algorithm is able to show the grid’s buses in which the THD achieve a maximum, and could help to choose the most appropriate one to put the electronic devices up, as active power filters, optimizing the system design, permitting the reduction of the system losses and an increase of the energy transmission effectiveness into the grid.
منابع مشابه
Harmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure
Thyristor rectifiers are widely used in electric railways in order to control the speed. As a consequence of their usage in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Regarding different p...
متن کاملCompensation of Voltage and Current Harmonics in Hybrid Renewable Energy System Using Coordinated Power Control of RES Inverter
In this paper, an adaptive control strategy is proposed for the inverters of renewable energy source (RES) to simultaneously control the load voltage, grid current and the amount of instantaneous injected power to the grid in the presence of grid voltage distortions and nonlinearity of load current. In the proposed control strategy, the power quality of the local load can be settled based on th...
متن کاملAn LCL-filtered Single-phase Multilevel Inverter for Grid Integration of PV Systems
Integration of the PV into the electrical grid needs power electronic interface. This power electronic interface should have some key features and should come up with grid codes. One of the important criteria is the quality and harmonic contents of the current being injected to the grid. High-order harmonics of the grid current should be very limited (lower than 0.3% of the fundamental current)...
متن کاملControl of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids
In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...
متن کاملModified Harmony Search Algorithm Based Unit Commitment with Plug-in Hybrid Electric Vehicles
Plug-in Hybrid Electric Vehicles (PHEV) technology shows great interest in the recent scientificliteratures. Vehicle-to-grid (V2G) is a interconnection of energy storage of PHEVs and grid. Byimplementation of V2G dependencies of the power system on small expensive conventional units canbe reduced, resulting in reduced operational cost. This paper represents an intelligent unitcommitment (UC) wi...
متن کاملA Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data
Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...