Bias Correction in Group Sequential Analysis with Correlated Data

نویسندگان

  • Roger P. Qu
  • David L. DeMets
  • R. W. Johnson
  • DAVID L. DEMETS
چکیده

This paper focuses on the bias of the group sequential estimate of treatment effect for correlated data using the generalized estimating equation (GEE) method and the Lan and DeMets alpha-spending function. Linear and logistic regressions are used to examine (a) the magnitude of the bias of a sequential estimate with correlated data; (b) the influence of the true correlation structure on bias. A bias-corrected sequential estimate is proposed using a Brownian motion approximation and numerical simulation. Logistic regression is used to illustrate and to assess the performance of the proposed method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative study of quantitative mapping methods for bias correction of ERA5 reanalysis precipitation data

This study evaluates the ability of different quantitative mapping (QM) methods as a bias correction technique for ERA5 reanalysis precipitation data. Climate type and geographical location can affect the performance of the bias correction method due to differences in precipitation characteristics. For this purpose, ERA5 reanalysis precipitation data for the years 1989-2019 for 10 selected syno...

متن کامل

روشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)

The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...

متن کامل

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

A Comparison of the Effectiveness of Cognitive Bias Modification in Real and Placebo Conditions on Attentional Bias and Approach Bias in Opium Abusers

Background & Aim: Inability to control drug use is considered a core aspect of drug dependency. Part of this inability is due to cognitive biases resulting from individuals’ constant usage of drugs. The aim of the present study was to compare the effectiveness of cognitive bias modification in real and placebo conditions on attentional bias and approach bias in opium abusers. Methods: This stud...

متن کامل

Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]

Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003