BACKGROUND The current clinical repair method used for the segmental peripheral nerve defect is autogenous nerve grafting. However, this method has several inherent disadvantages. Therefore, the authors have invented an alternative method for repairing the segmental peripheral nerve defect with a direct gradual lengthening of nerve stumps. In this study, for the clinical application, the authors developed a new external nerve-lengthening device for lengthening peripheral nerve stumps daily without anesthesia. METHODS In this study, a nerve segment 20 mm in length was resected from the rabbit sciatic nerve. In the nerve-lengthening group, direct nerve lengthening was performed in the proximal and distal nerve stumps at a rate of 1 mm/day without anesthesia. After being lengthened for 22 days, both proximal and distal nerve stumps were evaluated by immunohistochemical analysis. When confirming that both nerve stumps were successfully lengthened, a direct end-to-end neurorrhaphy was performed. As a control, 20-mm-long autografting was performed immediately after nerve resection. Nerve regeneration was evaluated by electrophysiologic and histologic examination at 16 weeks after the first operation in both the nerve-lengthening and the control groups. RESULTS The results of both electrophysiologic evaluation and histologic examination showed that the nerve-lengthening group performed significantly better than the autografting group. CONCLUSION The gradual nerve-lengthening procedure can be used as an alternative therapeutic method for repairing segmental peripheral nerve defects, which proved to be advantageous over widely adopted autogenous nerve grafting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prostaglandin E1 Combined with Chitosan Conduit Improves Sciatic Nerve Regeneration in Rats

Objective- To studylocal effect of prostaglandin E1on sciatic nerve regeneration Design- Experimental study Animals- Sixty male healthy white Wistar rats Procedures- Sixty animals were divided into four experimental groups (n = 15), randomly: Trasnsected (TC), Sham-operation (SHAM), control (CHIT) and prostagl...

متن کامل

Morphological Identification of Cell Death in Dorsal Root Ganglion Neurons Following Peripheral Nerve injury and repair in adult rat

Background: Axotomy causes sensory neuronal loss. Reconnection of proximal and distal nerve ends by surgical repair improves neuronal survival. It is important to know the morphology of primary sensory neurons after the surgical repair of their peripheral processes. Methods: Animals (male Wistar rats) were exposed to models of sciatic nerve transection, direct epineurial suture repair of sciati...

متن کامل

Successful Reconstruction of Nerve Defects Using Distraction Neurogenesis with a New Experimental Device

Introduction: Repair of peripheral nerve injuries is an intensive area of challenge and research in modern reconstructive microsurgery. Intensive research is being carried out to develop effective alternatives to the standard nerve autografting, avoiding its drawbacks. The aim of the study was to evaluate the effectiveness of a newly designed mechanical device for the reconstruction of the...

متن کامل

Use of Chitosan Conduit for Bridging Small-Gap Peripheral Nerve Defect in Sciatic Nerve Transection Model of Rat

Objective-To evaluate effect of chitosan conduit for peripheral nerve regeneration using sciatic nerve transection model in rat Design- Experimental in vivo study. Animals- Sixty healthy male Wistar rats. Procedures-The rats were divided into four experimental groups (n=15) randomly. In sham group the left sciatic nerve was exposed through a gluteal muscle incision and after careful...

متن کامل

Bridging Small-Gap Peripheral Nerve Defect Using Silicone Rubber Chamber in the Rat Sciatic Nerve Transection Model

  Despite promising results observed using silicone rubber chamber, no previous comprehensive work was performed on behavior of the conduit. Present study aimed at further functional, histomorphometrical and immunohistochemical assessment of nerve regeneration in the same animal along a 10-mm rat sciatic nerve gap. Fifty- four male Wistar rats were divided into three experimental groups (n = 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Plastic and reconstructive surgery

دوره 125 3  شماره 

صفحات  -

تاریخ انتشار 2010