A multiple-frequency hydrophone calibration technique.
نویسندگان
چکیده
A method is described for comparing the sensitivity of two hydrophones over the frequency range 1-15 MHz. This technique forms the basis for the dissemination of national ultrasonic standards in the U.K. over this frequency range. A reference hydrophone is placed in an ultrasonic field and then the device being calibrated is substituted and the two output voltages are compared. This substitution method utilizes a broadband ultrasonic field produced by nonlinear propagation. Thus it is possible to cover the whole frequency range with a single measurement on each hydrophone. The overall uncertainty in the intercomparison of two hydrophones increases from +/- 4.2% at 1 MHz to +/- 8.2% at 15 MHz (95% confidence level). The method has been compared with discrete-frequency substitution, time-delay spectrometry, and absolute calibrations using the National Physical Laboratory (NPL) Primary Standard Laser Interferometer. Various designs and sizes of hydrophones were compared, and agreement was within the combined random uncertainties for all the comparisons.
منابع مشابه
Phase calibration of hydrophones: heterodyne time-delay spectrometry and broadband pulse technique using an optical reference hydrophone
Two hydrophone calibration techniques are presented which provide amplitude and phase of hydrophone sensitivity. Heterodyne time-delay spectrometry can be applied in the frequency range from 0.5 to 50 MHz to all common hydrophones but needs a standard to obtain absolute values. A pulse technique between 1 and 70 MHz allows exploiting of an optical multilayer hydrophone as a phase standard. In c...
متن کاملHeterodyne and Time-gated Time-delay Spectrometry for Amplitude and Phase Calibration of Hydrophones
The determination of amplitude and phase of the hydrophone sensitivity using two techniques based on time-delay spectrometry is presented. The frequency range in which the technique can be applied is from 1 MHz to 50 MHz. The agreement with the results obtained by alternative calibration techniques is excellent, which emphasises the correct working of this coherent technique. Introduction Calib...
متن کاملThe Calibration of Hydrophones by a Novel Optical Technique in the Frequency Range 10 Khz to 600 Khz
This paper presents a technique for the absolute calibration of hydrophones using a novel optical method. The method uses a thin, optically reflecting membrane suspended in the acoustic field to allow optical measurement of the acoustic particle velocity using a Doppler interferometer. The hydrophone under test is then substituted for the pellicle, and the hydrophone response to the known acous...
متن کاملA New Method of Ultrasonic Hydrophone Calibration using Wave Propagation Modeling
A new method is presented for hydrophone calibration using the Khokhlov Zabolotskaya Kuznetsov (KZK) equation. Simulated and experimental on-axis finite amplitude distortion time waveforms and frequency spectra are compared. The hydrophone calibration up to 100 MHz is estimated for two different hydrophones.
متن کاملAbsolute Hydrophone Calibration to 40MHz Using Ultrasonic Far-Field
An absolute hydrophone calibration technique using ultrasonic far-field with optical interferometry was extended to 40MHz to evaluate the sound pressure amplitude generated by medical ultrasound equipment. A 1-mm nominal radius plane transducer was the calibration sound source for an ultrasonic far-field at 50mm propagation distance at 40MHz. The transducer’s effective radius was 0.88mm at 40MH...