A comparison of metered-dose inhaled albuterol versus endotracheal liquid bolus albuterol for the treatment of bronchoconstriction.

نویسندگان

  • Donald A Johnston
  • Tim W Gilmore
  • Kevin P Gosselin
چکیده

INTRODUCTION Aerosolized albuterol delivery is a mainstay treatment for bronchoconstriction; however, almost no data exist that evaluate the clinical outcome of instillation of an endotracheal liquid bolus (ELB) of a bronchodilator directly into the airway. METHODS This randomized trial sought to evaluate the efficacy of albuterol lavage via artificial airway with accompanied patient positioning. Subjects receiving mechanical ventilation for acute respiratory failure with clinical manifestations of bronchoconstriction were assigned to initially receive either traditional albuterol via metered-dose inhaler (MDI) or albuterol via ELB lavage with follow-up administration of the other therapy after a 4-h washout period. Clinical data were collected at baseline and at 5 and 30 min post-treatment. RESULTS Fourteen subjects (5 males, 9 females; mean age of 57.5 y) were included in this study. In the group receiving initial ELB, peak airway pressure decreased significantly (P = .02), and a significant decrease in airway resistance mean scores was seen from baseline to 30 min post-treatment (P < .001) and from 5 to 30 min post-treatment (P = .003), with no significant effects seen with follow-up MDI. In the initial MDI treatment group, no significant effect on peak airway pressure or airway resistance was noted. S(pO2) increased at 5 min post-treatment with ELB. In contrast, S(pO2) decreased 30 min post-treatment with MDI. Mean arterial pressure decreased post-treatment with ELB. The pattern in heart rate change post-treatment with ELB was similar to that post-treatment with MDI, with a significant increase at the 5-min interval from baseline (P < .01), followed by a significant decrease at the 30-min interval (P < .001). There were no differences in dynamic compliance at each time interval following administration of both the MDI (P = .92) and ELB conditions (P = .18). CONCLUSIONS ELB albuterol lavage may be a viable option to reverse bronchoconstriction in intubated patients with limited response to traditional aerosolized albuterol via MDI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Racial stereotyping: survey of psychiatrists in the United Kingdom.

responses to salbutamol using Diskhaler versus metered-dose inhaler. Comparison of the bronchodilating efficacies of a novel salbutamol metered dose powder inhaler and a pressurised metered dose aerosol with a spacer. Efficacy of a new non-ozone depleting formulation for salbutamol. Comparison of inhaled ter-butaline administered by either the Turbuhaler dry powder or a metered-dose inhaler wit...

متن کامل

Intratracheal albuterol: a potential intervention for the asthma toolbox.

In this issue of RESPIRATORY CARE, Johnston et al1 remind us of a route of medication delivery that is often overlooked: intratracheal. The stimulus for the project was the death of children with a severe asthma attacks who had received numerous doses of albuterol by metered-dose inhaler (MDI), yet had no relief. The purpose of this study was to compare the effectiveness of liquid bolus adminis...

متن کامل

Bronchodilator response to albuterol after regular formoterol and effects of acute corticosteroid administration.

BACKGROUND There is controversy about the development of bronchodilator subsensitivity after regular administration of long-acting beta(2)-agonists. OBJECTIVES The purpose of the study was to evaluate whether regular treatment with formoterol affects the bronchodilator response to repeated puffs of albuterol, and also to assess the effects of acute administration of a bolus dose of IV or inha...

متن کامل

Comparison of the effect of broncodiatory albotrol from spacer and nebulazor foe freatment of Astma patients

Tavana S1, Nadi E1, Ansari M2, zeraati F3, Hashemi H1, Mani Kashani Kh4, Mavallat M5 1. Assistant professor, Department of internal, Faculty of medicine, Hamedan University of medical sciences 2. Associate professor, Department of internal, Faculty of medicine, Hamedan University of medical sciences 3. Associate professor, Department of Pharmacology, Faculty of medicine, Hamedan Univers...

متن کامل

Albuterol aerosol delivered via metered-dose inhaler to intubated pediatric models of 3 ages, with 4 spacer designs.

OBJECTIVE To determine the amount of albuterol, in various particle size ranges, delivered from a hydrofluoroalkane-propelled metered-dose inhaler (Airomir) in 3 models of pediatric intubation (ages 8 months, 4 years, and 16 years) using 4 types of aerosol reservoir: 3 spacers (ACE, AeroChamber HC MV, metal NebuChamber without 1-way valve) and 1 holding chamber (metal NebuChamber with 1-way val...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 60 5  شماره 

صفحات  -

تاریخ انتشار 2015