Prediction of small-for-gestational-age neonates: screening by fetal biometry at 35-37 weeks.
نویسندگان
چکیده
OBJECTIVE To investigate the value of fetal biometry at 35-37 weeks' gestation in the prediction of delivery of small-for-gestational-age (SGA) neonates, in the absence of pre-eclampsia (PE). METHODS This was a screening study in singleton pregnancies at 35-37 weeks' gestation, comprising 278 that delivered SGA neonates with a birth weight < 5th percentile and 5237 cases unaffected by SGA, PE or gestational hypertension. Multivariable logistic regression analysis was used to determine if screening by a combination of maternal factors and Z-scores of fetal head circumference (HC), abdominal circumference (AC) and femur length (FL) or estimated fetal weight (EFW) had a significant contribution to the prediction of SGA neonates. RESULTS Multivariable logistic regression analysis demonstrated that the likelihood of delivering a SGA neonate with a birth weight < 5th percentile decreased with maternal weight and height, and in parous women the risk increased with a longer interpregnancy interval. The risk was higher in women of Afro-Caribbean and South Asian racial origins, in cigarette smokers, nulliparous women and in those with history of SGA, with or without prior PE. Combined screening by maternal characteristics and history with EFW Z-scores at 35-37 weeks predicted 89% of SGA neonates with birth weight < 5th percentile delivering < 2 weeks following assessment, at a 10% false-positive rate (FPR). The respective detection rate for the prediction of SGA neonates delivering ≥ 37 weeks' gestation was 70%. The performance of screening by a combination of Z-scores of fetal HC, AC and FL was similar to that achieved by the EFW Z-score. CONCLUSION Combined testing by maternal characteristics and fetal biometry at 35-37 weeks could identify, at a 10% FPR, about 90% of pregnancies that subsequently deliver SGA neonates within 2 weeks of assessment and 70% of those that deliver ≥ 37 weeks.
منابع مشابه
Prediction of large-for-gestational-age neonates: screening by maternal factors and biomarkers in the three trimesters of pregnancy.
OBJECTIVE To develop a model based on maternal characteristics and medical history (maternal factors) for the prediction of delivery of large-for-gestational-age (LGA) neonates, and to examine the potential value of first-, second- and third-trimester fetal biometry and biomarkers in improving such a model. METHODS This was a screening study in 76 300, 54 999, 25 727 and 6181 singleton pregna...
متن کاملPrediction of small-for-gestational-age neonates: screening by placental growth factor and soluble fms-like tyrosine kinase-1 at 35-37 weeks.
OBJECTIVE To investigate the potential value of maternal serum placental growth factor (PlGF) and soluble fms-like tyrosine kinase-1 (sFlt-1) at 35-37 weeks' gestation in the prediction of delivery of small-for-gestational-age (SGA) neonates, in the absence of pre-eclampsia (PE). METHODS This was a screening study in singleton pregnancies at 35-37 weeks, including 158 that delivered SGA neona...
متن کاملPrediction of small-for-gestational-age neonates: screening by fetal biometry at 30-34 weeks.
OBJECTIVE To investigate the value of fetal biometry at 30-34 weeks' gestation in the prediction of delivery of small-for-gestational-age (SGA) neonates, in the absence of pre-eclampsia (PE). METHODS This was a screening study in 30 849 singleton pregnancies at 30-34 weeks' gestation, comprising 1727 that delivered SGA neonates with a birth weight < 5(th) percentile and 29 122 cases unaffecte...
متن کاملImpact on obstetric outcome of third-trimester screening for small-for-gestational-age fetuses.
OBJECTIVES To evaluate the performance of screening for small-for-gestational-age (SGA) fetuses by ultrasound biometry at 30-35 weeks' gestation, and to determine the impact of screening on obstetric and neonatal outcomes. METHODS For this prospective cohort study, pregnant women were recruited from two French university maternity centers between 2003 and 2006. Performance measures of third-t...
متن کاملPrediction of small-for-gestational-age neonates: screening by fetal biometry at 19-24 weeks.
OBJECTIVE To investigate the value of fetal biometry at 19-24 weeks' gestation in the prediction of delivery of small-for-gestational-age (SGA) neonates, in the absence of pre-eclampsia (PE), and examine the potential value of such assessment in deciding whether the third-trimester scan should be at 32 and/or 36 weeks' gestation. METHODS This was a screening study in 88,187 singleton pregnanc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
دوره 45 5 شماره
صفحات -
تاریخ انتشار 2015