Infrared laser thermal fusion of blood vessels: preliminary ex vivo tissue studies.
نویسندگان
چکیده
Suture ligation of blood vessels during surgery can be time-consuming and skill-intensive. Energy-based, electrosurgical, and ultrasonic devices have recently replaced the use of sutures and mechanical clips (which leave foreign objects in the body) for many surgical procedures, providing rapid hemostasis during surgery. However, these devices have the potential to create an undesirably large collateral zone of thermal damage and tissue necrosis. We explore an alternative energy-based technology, infrared lasers, for rapid and precise thermal coagulation and fusion of the blood vessel walls. Seven near-infrared lasers (808, 980, 1075, 1470, 1550, 1850 to 1880, and 1908 nm) were tested during preliminary tissue studies. Studies were performed using fresh porcine renal vessels, ex vivo, with native diameters of 1 to 6 mm, and vessel walls flattened to a total thickness of 0.4 mm. A linear beam profile was applied normal to the vessel for narrow, full-width thermal coagulation. The laser irradiation time was 5 s. Vessel burst pressure measurements were used to determine seal strength. The 1470 nm laser wavelength demonstrated the capability of sealing a wide range of blood vessels from 1 to 6 mm diameter with burst strengths of 578 ± 154, 530 ± 171, and 426 ± 174 mmHg for small, medium, and large vessel diameters, respectively. Lateral thermal coagulation zones (including the seal) measured 1.0 ± 0.4 mm on vessels sealed at this wavelength. Other laser wavelengths (1550, 1850 to 1880, and 1908 nm) were also capable of sealing vessels, but were limited by lower vessel seal pressures, excessive charring, and/or limited power output preventing treatment of large vessels (>4 mm outer diameter).
منابع مشابه
Rapid sealing and cutting of porcine blood vessels, ex vivo, using a high-power, 1470-nm diode laser.
Suture ligation with subsequent cutting of blood vessels to maintain hemostasis during surgery is time consuming and skill intensive. Energy-based electrosurgical and ultrasonic devices are often used to replace sutures and mechanical clips to provide rapid hemostasis and decrease surgery time. Some of these devices may create undesirably large collateral zones of thermal damage and tissue necr...
متن کاملMid-infrared laser orbital septal tightening: ex vivo dosimetry study and pilot clinical study.
IMPORTANCE Blepharoplasty is one of the most commonly performed facial aesthetic surgeries. While myriad techniques exist to improve the appearance of the lower eyelids, there is no clear consensus on the optimal management of the orbital septum. OBJECTIVES To evaluate the safety and feasibility of the use of the holmium:yttrium aluminum garnet (Ho:YAG) laser for orbital septal tightening, an...
متن کاملHeat generation during ablation of porcine skin with erbium:YAG laser vs a novel picosecond infrared laser.
IMPORTANCE Despite significant advances in surgery, most surgical tools remain basic. Lasers provide a means of precise surgical ablation, but their clinical use has remained limited because of undesired thermal, ionizing, or acoustic stress effects leading to tissue injury. A novel ultrafast, nonionizing, picosecond infrared laser (PIRL) system has recently been developed and is capable, in th...
متن کامل450 nm Blue Laser and Oral Surgery: Preliminary ex vivo Study.
INTRODUCTION Dental diode lasers were started to be used at the end of the 1990s and were shown to possess several important characteristics, such as small size and low cost, as well as the advantage of optic fibers delivering system. Although only two wavelengths (810 and 980 nm) had been the most used dental diode lasers, a wavelength emitting in the blue portion of the spectrum has recently ...
متن کاملHigh-power laser vaporization of the canine prostate using a 110 W Thulium fiber laser at 1.91 microm.
INTRODUCTION The Thulium fiber laser may have several advantages over current urology lasers, including smaller size, more efficient operation, improved spatial beam quality, more precise tissue incision, and operation in pulsed or continuous-wave modes. Previous laser-tissue interaction studies utilizing the Thulium fiber laser have been limited to laser powers of less than 5 W, restricting po...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 18 5 شماره
صفحات -
تاریخ انتشار 2013