A Study on Design Optimization of Compton Suppression Detector for in Situ Measurement of Site Using Monte Carlo Techniques
نویسندگان
چکیده
Compton suppression system was established to accurately and precisely measure low-level radiation during insitu measurement of sites. HPGe detector was selected as the main detector and plastics scintillation detector was selected as the guard detector. Using Cs source, while changing the height(h) and width(w) about plastic scintillation detector the gamma spectrum was simulated using the Monte Carlo method. Also each was performance evaluated using reduction factor (RF). As a result the optimum result of height(h) 10cm x width(W) 10cm, –1cm forward disposition of plastic detector size was derived. The reduction factor (RF) according to optimum design condition was 2.97, and a maximum of 5.0 suppression effect was obtained near to the 420keV.
منابع مشابه
Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5
Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...
متن کاملA performance study of the conceptual implementation of the GEM-tracking detector in Monte Carlo simulation
PANDA experiment (antiProton ANnihilation at DArmstadt) is one of the key projects of the future FAIR facilities to investigate the reactions of antiprotons with protons and nuclear targets. experiment is designed to serve as a completely extraordinary physical potential due to exploiting the availability of cold and high-intensity beams of antiprotons. One of the significant parts of the ...
متن کاملStudy of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method
Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center ...
متن کاملEvaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملMonte Carlo-based optimization of a gamma probe system for sentinel lymph node mapping
Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in...