Repeated fracture of pacemaker leads with migration into the pulmonary circulation and temporary pacemaker wire insertion via the azygous vein.

نویسندگان

  • A R Udyavar
  • U M Pandurangi
  • K Latchumanadhas
  • A S Mullasari
چکیده

Repeated implantation of pacemaker in the same patient is a common occurrence because of the increased longevity of patients. However, repeated lead fracture in the same patient and migration of the pacemaker lead into the pulmonary circulation is rare. We describe a 56-year-old gentleman who had undergone pacemaker implantations thrice due to repeated lead fractures (thrice) and also had migration of the pacemaker lead into the pulmonary circulation. He also had an azygous vein which was noticed while placing the temporary pacemaker wire.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ffect of Chlorhexidine on Prevention of Local Infection in Temporary Transvenous Pacemaker Catheter Site

Background and Objectives: The local infection of temporary transvenous pacemaker catheter site is a common hospital acquired infections. This study aimed to assess the effect of the Chlorhexidine Glaciate 2% on prevention of local infection on temporary transvenous pacemaker catheter site. Materials and Methods: In this 7-month randomized controlled trial, 100 patients having temporary transve...

متن کامل

بلوک کامل قلبی مادرزادی، معرفی یک مورد و مرور مقالات مشابه

Abstract: Background and Aim: Since electrocardiography (ECG) is essential for the diagnosis of pediatric asymptomatic Complete Heart Block (CHB) and it is not usually done in the preoperative evaluation of asymptomatic children, physicians might confront with asymptomatic cases of CHB at anesthesia induction. Case Report: In this study, we introduced a 31-month-old boy who faced CHB after anes...

متن کامل

بررسی نیازهای آموزشی مراقبت از خود بیماران درای دستگاه ضربان ساز دائم در بیمارستان قلب شهید رجائی در سال 73-1372

A field study was made to investigate the learning needs of patients with pacemaker in Shahid Rajaii Heart Hospital's out-patient clinic (1994). A total of 60 patients with pacemaker were selected sequentially from the total population that had a pacemaker and attended the out-patient clinic in shahid Rajaii Hospital. The subjects met the criteria for participating in this study. The tool was a...

متن کامل

Silent obstruction of SVC with collateral circulation after cardioverter defibrillator implantation.

A 47-year-old woman with dilated cardiomyopathy underwent a single-chamber implantable cardioverter defibrillator (ICD) implantation for sustained ventricular tachycardia 10 years previously. Because bradycardia became clinically evident with beta-blocker therapy for heart failure, we attempted an upgrade from a single-chamber to dual-chamber ICD for physiological pacing. Venography revealed co...

متن کامل

Idiopathic left innominate vein stenosis during pacemaker implantation with venoplasty in a retrograde approach

Introduction Left innominate stricture or stenosis after hemocatheter insertion or pacemaker lead insertion is not an uncommon vascular complication. However, spontaneous left innominate venous stricture has not been reported. We present a case with spontaneous left innominate vein stenosis in a patient with history of open heart surgery during pacemaker implantation. Retrograde channel from th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of postgraduate medicine

دوره 54 1  شماره 

صفحات  -

تاریخ انتشار 2008