Recurrent syncope 31 years after mitral valve replacement.
نویسندگان
چکیده
A 43-year—old man was admitted to the coronary care unit because of recurrent syncope. His medical history included pulmonic valve angioplasty at age 9 years, mechanical mitral valve replacement because of severe mitral regur-gitation caused by congenital atrioventricular canal, and pacemaker implantation because of complete atrioventricular block. On admission he was orthopneic, his blood pressure was 78/45 mm Hg, and his pulse was 72 beats per minute, irregular. On auscultation, lungs were clear and there were irregular cardiac sounds of mechanical mitral prosthesis. There were no signs of peripheral edema. ECG showed slow atrial fibrillation with intermittent ventricular pacing. International normalized ratio was in high therapeutic range, at 4.5. Echo examination showed intermittent opening of the mitral valve 1:2. This was confirmed by continuous wave Doppler, M-mode echo, and color M-mode echo (Figure) with mildly elevated gradient 20/8 mm Hg. Cine fluoroscopy showed intermittent opening of the mitral prosthesis (online-only Data Supplement Movie I; Bjork-Shiley mono-leaflet tilting disk). The patient underwent surgery. Massive calcified pan-nus covered the valve and interfered with the opening of the prosthesis. Intermittent opening of prosthetic mitral valve is rare 1–4 and occurs with mono-leaflet tilting disk prosthesis as in our case, 10 to 23 years after initial surgery; in our case it was 31 years after mitral valve replacement. The international normalized ratio is usually in the therapeutic range. Surgical exploration reveals pannus that interferes with valvular function and usually needs replacement of the prosthesis. In our case the pannus was successfully and completely removed from the prosthetic valve. Intermittent opening of mitral valve prosthe-sis may be easily missed, because the gradient on the prosthe-sis may be near normal. Cine fluoroscopy is very helpful in these cases, but accurate echo examination with recording of several sequential beats remains an irreplaceable technique. in cardiovascular medicine: intermittent trapping of a tilting-disc mitral prosthesis. Intermittent opening of a mechanical mitral valve prosthesis due to pannus formation; report of a case [in Japanese]. Intermittent opening of a mitral valve tilting disc prosthesis 23 years after implantation caused by circumferential pannus. Diagnosis of intermittent obstruction of mechanical mitral valve prostheses by Doppler echocardiography.
منابع مشابه
Right sided heart evaluation after successful mitral valve replacement.
Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...
متن کاملSurgical Treatment of Rheumatic Mitral Valve Lesions in Children and Adolescents
Rheumatismal lesions of the mitral valve a!I'e rare under the age of six and surgical irutervention in symptomatic patients is an academic problem. Early surgical treatment has been done to prevent serious changes and unreversib1e complications o.f the heart and lungs. From April 71 until April 74, thirty-five patient, ranging between 8-18 years of age, suffering of <lifferents heart ,tro...
متن کاملComparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery
Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...
متن کاملHealth-Related Quality of Life after Valve Replacement Surgery
Background: Heart valve disease gradually increases the pressure in the heart chambers and impairs heart pumping. It influences on quality of life due to low output, disability, fear, amnesia, anxiety, and depression. Although most of signs and symptoms in patients with heart valve diseases may significantly decrease after valve replacement surgery, there is limited information about the impact...
متن کاملSuccessful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis
Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...