High-energy resolution alpha spectrometry using cryogenic detectors.
نویسندگان
چکیده
Applications such as environment monitoring implying alpha emitters activity measurement associated with isotope identification, require high-energy resolution detectors. Conventional silicon detectors are inexpensive therefore widely used, although intrinsically limited in energy resolution. Thermal detection principle of cryogenic detectors introduces a breakthrough in alpha particle measurement. For the first time, spectra with 5.5 keV FWHM energy resolution have been obtained for several external alpha emitting sources using a copper-germanium bolometer specially developed for alpha spectrometry.
منابع مشابه
Energy-sensitive cryogenic detectors for high-mass biomolecule mass spectrometry.
Energy-sensitive calorimetric detectors that operate at low temperatures ("cryogenic detectors") have recently been applied for the first time as ion detectors in time-of-flight mass spectrometry. Compared to conventional, ionization-based detectors, which rely on secondary electron formation or the charge created in a semiconductor, cryogenic detectors measure low-energy solid state excitation...
متن کاملA Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region
Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...
متن کاملCryogenic X-ray detectors for synchrotron science.
Cryogenic detectors operated at temperatures below 1 K offer an order of magnitude higher energy resolution than conventional semiconductor-based energy-dispersive detectors, and orders of magnitude higher efficiency that grating spectrometers. Initially developed for astrophysics applications, these detectors are increasingly used in synchrotron-based research, both for detector characterizati...
متن کاملشبیه سازی یک آشکارساز تناسبی میکرو نواری برای آشکارسازی گاز رادن و دختران با کد مونت کارلو (MCNPX)
Many detection methods have been applied to detect radon gas. Due to the low noise and high resolution of gas detectors compared to semiconductor detectors or scintillation detectors, using them to detect alpha radiation is very considerable. Microstrip proportional detector is also included in this group and it has not been used for the detection of radon. In this article, response of the micr...
متن کاملIndustrial X-Ray Fluorescence Analysis- New Applications and Challenges for Cryogenic Detectors
Cryogenic, high-resolution X-ray detectors have potential applications in industrial .X-ray fluorescence (XRF) analysis. We discuss various XRF analysis techniques currently used in the semiconductor industry, problems encountered clue to limitations of current detectors and the potential benefits of using cryogen ic detectors in these applications. We give examples of demonstration experiments...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
دوره 64 10-11 شماره
صفحات -
تاریخ انتشار 2006