A new manual method for assessing elbow valgus laxity
نویسندگان
چکیده
BACKGROUND A screening of ulnar collateral ligament insufficiency is required for overhead throwers, since secondary pathologic changes result from an increased elbow valgus laxity. We developed a new manual method for assessing elbow valgus laxity and investigated the reliability of this method and its correlation with ultrasonographic assessment. METHODS We defined elbow valgus laxity as the difference between the shoulder external rotation angle (ER angle) measured with the elbow in 90 degrees flexion and that measured with the elbow in extension because ER angle measured with the elbow in 90 degrees flexion includes elbow valgus laxity and ER angle with the elbow in extension does not include it. ER angle measurement with the elbow in extension involved the use of a custom arm holder. Three examiners each measured elbow valgus laxity by the new method in 5 healthy volunteers. Intraobserver and interobserver reliability was evaluated by calculating the intraclass correlation coefficient. We then assessed 19 high-school baseball players with no complaints of shoulder or elbow pain. Elbow ultrasonography was performed with a 10-MHz linear transducer with the elbow in 90 degrees flexion, and the forearm in the neutral position, and the width of the medial joint space at the level of the anterior bundle was measured. Elbow valgus laxity assessed by ultrasonography was defined as the difference between the medial joint space width with gravity stress and that without gravity stress. Increased elbow valgus laxity assessed by both our method and ultrasonography was defined as the difference between the laxity of the elbow on the throwing side and that on the contralateral side. Pearson's correlation coefficient (r) was calculated to evaluate the relationship between increased elbow valgus laxity obtained by our manual method and that by ultrasonography. RESULTS Intraobserver reliability ranged from 0.92 to 0.98, and interobserver reliability was 0.70. The increased elbow valgus laxity assessed by our method was significantly correlated with that assessed by ultrasonographic assessment (P = 0.019, r = 0.53). CONCLUSIONS Elbow valgus laxity can be assessed by our method. This method may be useful for screening for insufficiency of the ulnar collateral ligament.
منابع مشابه
Impact of Ulnar Collateral Ligament Tear on Posteromedial Elbow Biomechanics.
Ulnar collateral ligament insufficiency has been shown to result in changes in contact pressure and contact area in the posteromedial elbow. This study used new digital technology to assess the effect of a complete ulnar collateral ligament tear on ulnohumeral contact area, contact pressure, and valgus laxity throughout the throwing motion. Nine elbow cadaveric specimens were tested at 90° and ...
متن کاملSingle-strand ligament reconstruction of the medial collateral ligament restores valgus elbow stability.
The purpose of this study was to determine the contribution of the central portion of the anterior bundle of the medial collateral ligament (MCL) to elbow stability and to evaluate the effectiveness of a single-strand MCL reconstruction in restoring elbow stability. Testing of 11 fresh-frozen upper extremities was first performed on the intact elbow and then with the capsule, flexor-pronator mu...
متن کاملBiomechanical Evaluation of Ulnar Collateral Ligament Reconstruction of the Elbow Using the Docking Technique
INTRODUCTION In the functional range of elbow flexion (approximately 20 to 120) the anterior bundle of the Ulnar Collateral Ligament (UCL) has been shown to function as the primary stabilizer against valgus stresses [1,2]. Injuries to this ligament are common among throwing athletes. Surgical reconstruction of the UCL is frequently performed using the Docking technique [3] and has achieved succ...
متن کاملAssessment of elbow joint kinematics in passive motion by electromagnetic motion tracking.
This research provides a detailed analysis of the kinematics of passive elbow motion. It quantifies how closely humeroulnar kinematics approximates rotation around a fixed axis. The results are clinically relevant for emerging treatment modalities that impose an artificial hinge to the elbow joint, such as total elbow arthroplasty and articulated external fixation. In a cadaveric study of seven...
متن کاملMedial elbow joint laxity in professional baseball pitchers. A bilateral comparison using stress radiography.
Injuries to the ulnar collateral ligament frequently occur in throwing athletes because of large, repetitive valgus stresses to the elbow during the cocking and acceleration phases of throwing. Identification of injury to this ligament is important in evaluating the throwing elbow. The purpose of this study was to determine whether differences in medial elbow laxity exist between the dominant a...
متن کامل