Effect of mini-implant length and diameter on primary stability under loading with two force levels.
نویسندگان
چکیده
Mini-implants are widely utilized as anchorage units in orthodontic treatment. Nevertheless, there are factors that interfere with their clinical performance. The aim of this study was to examine the impact of length and diameter on the primary stability of two different types of orthodontic mini-implants loaded with two force levels. A total of 90 self-drilling mini-implants were inserted in bovine ribs in vitro, 62 of which were used in data analysis. The mini-implants were of two types, Aarhus (n=29) and Lomas (n=33), of two lengths (7 and 9 mm, n=26 and n=28, respectively), and of two diameters (1.5 and 2 mm, Lomas only, n=6 and n=8, respectively). A closed nickel-titanium (NiTi) coil spring was attached to each mini-implant. Half of the preparations were loaded with a low force of 0.5 N and the other half with a force of 2.5 N. Mini-implant deflections during force application were non-invasively registered using a three-dimensional (3D) laser-optical system. The results were analysed with analysis of variance for the effects of implant type, implant length, and force level, and with a t-test for the study of the effect of diameter in two different diameter variants of the same (Lomas) implant. In the low-force group, implant displacements were not statistically significant difference according to the investigated parameters. In the high-force group, the 9 mm long mini-implants displaced significantly less (10.5±7.5 μm) than the 7 mm long (22.3±11.3 μm, P<0.01) and the 2 mm wide significantly less (8.8±2.2 μm) than the 1.5 mm implants (21.9±1.5 μm, P<0.001). The force level at which significance occurred was 1 N. The rotation of the Lomas mini-implants in the form of tipping was significantly higher than that of the Aarhus mini-implants at all force levels. Implant length and diameter become statistically significant influencing parameters on implant stability only when a high force level is applied.
منابع مشابه
Analysis on the stress of the bone surrounding mini-implant with different diameters and lengths under torque.
The purpose of this study is to compare the stress of the bone around the mini-implant under the two kinds of force: the composite force which contains torque and traditional single force. There were 96 finite element models formed by the combination of mini-implant and bone, with diameters of 1.2 mm, 1.6 mm, 2.0 mm and corresponding length being 6 mm, 8 mm, 10 mm, 12 mm, respectively. Each siz...
متن کاملImmediate loading in dental implants ( A literature review )
Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...
متن کاملEvaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملClinical evaluation of the stability of implants placed at different supracrestal levels
PURPOSE The aim of this study was to evaluate the stability during healing and before loading of implants placed at two different supracrestal levels according to their collar texture. MATERIALS AND METHODS This retrospective study included patients who received posterior implants with the same macro design. Implants with a machined collar were placed 0.3 mm above the crestal bone (M group), ...
متن کاملComparison of the Effect of Two Different Abutment Diameters on Detorque Value Using Cyclic Loading and Thermocycling
Background and Aim: Screw loosening is a common problem with both screw-retained and cemented implant restorations. It is assumed that the abutment diameter affects detorque value and screw loosening. We aimed to determine the effect of two different abutment diameters on detorque value using cyclic loading and thermocycling. Materials and Methods: This in-vitro experimental study was conducte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of orthodontics
دوره 33 4 شماره
صفحات -
تاریخ انتشار 2011