Pitfalls of high-pass filtering for detecting epileptic oscillations: a technical note on "false" ripples.

نویسندگان

  • C G Bénar
  • L Chauvière
  • F Bartolomei
  • F Wendling
چکیده

OBJECTIVES To analyze interictal High frequency oscillations (HFOs) as observed in the medial temporal lobe of epileptic patients and animals (ripples, 80-200Hz and fast ripples, 250-600Hz). To show that the identification of interictal HFOs raises some methodological issues, as the filtering of sharp transients (e.g., epileptic spikes or artefacts) or signals with harmonics can result in "false" ripples. To illustrate and quantify the occurrence of false ripples on filtered EEG traces. METHODS We have performed high-pass filtering on both simulated and real data. We have also used two alternate methods: time-frequency analysis and matching pursuit. RESULTS Two types of events were shown to produce oscillations after filtering that could be confounded with actual oscillatory activity: sharp transients and harmonics of non-sinusoidal signals. CONCLUSIONS High-pass filtering of EEG traces for detection of oscillatory activity should be performed with great care. Filtered traces should be compared to original traces for verification of presence of transients. Additional techniques such as time-frequency transforms or sparse decompositions are highly beneficial. SIGNIFICANCE Our study draws the attention on an issue of great importance in the marking of HFOs on EEG traces. We illustrate complementary methods that can help both researchers and clinicians.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Separation between spikes and oscillation by SWT implemented on embedded architecture

Several strategies have already been proposed for separating these activities in an offline approach. However, it would be very interesting to have embedded systems, which could be used on realtime patient monitoring systems, either for early detection of seizures or for neurofeedback techniques. These filtering techniques can be expensive in computing time, which limits the current capabilitie...

متن کامل

Automatic detection of fast ripples 1

Highlights 1 1) We propose a novel method for automatically detecting fast ripples (FRs, 250-600 Hz) 2 2) The signal energy in low and high frequency bands is used to classify EEG events as FRs, interictal 3 epileptic spikes or artifacts. 4 3) The sensitivity and the specificity of this method is high enough to avoid " false ripples " caused by 5 sharp transients. 6 7 8 9 Abstract 10 Objective:...

متن کامل

Interictal high-frequency oscillations (100-500 Hz) in the intracerebral EEG of epileptic patients.

Interictal fast oscillations between 100 and 500 Hz have been reported in signals recorded from implanted microelectrodes in epileptic patients and experimental rat models. Oscillations between 250 and 500 Hz, or fast ripples (FR), appeared related to the epileptic focus whereas ripples (80-200 Hz) were not. We report high-frequency oscillations recorded with intracranial macroelectrodes in sev...

متن کامل

Parallelizing Electroencephalogram Processing on a Many-Core Platform for the Detection of High Frequency Oscillations

EEG high frequency oscillations, known as ripples, in subdural Electroencephalography (EEG) have been associated to the seizure onset zone. Ripples, which can be visible in the frequency range from 80 to 250 Hz, are considered reliable biomarkers (like interictal EEG spikes) to identify the epileptic focus in the brain. Consequently, an automated detection method is proposed with the aim of ide...

متن کامل

Emergent dynamics of fast ripples in the epileptic hippocampus.

Fast ripples are a type of transient high-frequency oscillations recorded from the epileptogenic regions of the hippocampus and the temporal cortex of epileptic humans and rodents. These events presumably reflect hypersynchronous bursting of pyramidal cells. However, the oscillatory spectral content of fast ripples varies from 250 to 800 Hz, well above the maximal firing frequency of most hippo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology

دوره 121 3  شماره 

صفحات  -

تاریخ انتشار 2010