Evaluation of graphic cardiovascular display in a high-fidelity simulator.

نویسندگان

  • James Agutter
  • Frank Drews
  • Noah Syroid
  • Dwayne Westneskow
  • Rob Albert
  • David Strayer
  • Julio Bermudez
  • Matthew B Weinger
چکیده

UNLABELLED "Human error" in anesthesia can be attributed to misleading information from patient monitors or to the physician's failure to recognize a pattern. A graphic representation of monitored data may provide better support for detection, diagnosis, and treatment. We designed a graphic display to show hemodynamic variables. Twenty anesthesiologists were asked to assume care of a simulated patient. Half the participants used the graphic cardiovascular display; the other half used a Datex As/3 monitor. One scenario was a total hip replacement with a transfusion reaction to mismatched blood. The second scenario was a radical prostatectomy with 1.5 L of blood loss and myocardial ischemia. Subjects who used the graphic display detected myocardial ischemia 2 min sooner than those who did not use the display. Treatment was initiated sooner (2.5 versus 4.9 min). There were no significant differences between groups in the hip replacement scenario. Systolic blood pressure deviated less from baseline, central venous pressure was closer to its baseline, and arterial oxygen saturation was higher at the end of the case when the graphic display was used. The study lends some support for the hypothesis that providing clinical information graphically in a display designed with emergent features and functional relationships can improve clinicians' ability to detect, diagnose, manage, and treat critical cardiovascular events in a simulated environment. IMPLICATIONS A graphic representation of monitored data may provide better support for detection, diagnosis, and treatment. A user-centered design process led to a novel object-oriented graphic display of hemodynamic variables containing emergent features and functional relationships. In a simulated environment, this display appeared to support clinicians' ability to diagnose, manage, and treat a critical cardiovascular event in a simulated environment. We designed a graphic display to show hemodynamic variables. The study provides some support for the hypothesis that providing clinical information graphically in a display designed with emergent features and functional relationships can improve clinicians' ability to detect, diagnosis, mange, and treat critical cardiovascular events in a simulated environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determining the Proper compression Algorithm for Biomedical Signals and Design of an Optimum Graphic System to Display Them (TECHNICAL NOTES)

In this paper the need for employing a data reduction algorithm in using digital graphic systems to display biomedical signals is firstly addressed and then, some such algorithms are compared from different points of view (such as complexity, real time feasibility, etc.). Subsequently, it is concluded that Turning Point algorithm can be a suitable one for real time implementation on a microproc...

متن کامل

A Cybernetic Approach To Assess Flight Simulator Fidelity

This paper presents the results of an experiment in which a cybernetic approach has been used to investigate the effect of motion filter setting changes and display type on simulator fidelity. Pilot control behavior, pilot remnant, open loop behavior, open loop performance and subjective evaluations in a real jet-aircraft were compared with that in a high-fidelity motion base simulator. The tas...

متن کامل

Calling While Driving: Effects of a Remote Traffic Display

Cell phone conversations distract drivers. This research explores the possibility of reducing distracting by providing callers with a remote display of the driver’s traffic. We asked whether providing such contextual information would change the caller’s conversation such that drivers would be less distracted. In Experiment 1 we examined this question in a low-fidelity driving simulator; in Exp...

متن کامل

Many Moving Parts: Evaluating the Implementation of the Kin KeeperSM Cancer Prevention Intervention

Introduction: This paper details an evaluation of the implementation and feasibility of a multilevel project entitled Kin KeeperSM Cancer Prevention Intervention that utilizes community health workers (CHWs) to deliver breast and cervical cancer education. The evaluation includes intervention fidelity, participant satisfaction, participant retention, and the cost of program implementa...

متن کامل

COTS and Design Pattern Based High Fidelity Flight Simulator Prototype System

Flight simulator is among the most sophisticated software systems in existence. It is highly distributed, has rigorous timing requirements, and must be amenable to frequent updates to maintain high fidelity with the everchanging vehicle and environment it is simulating. Current flight simulation framework and software developing pattern are complicated to use and time consuming. We have accompl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 97 5  شماره 

صفحات  -

تاریخ انتشار 2003