Commentary Folding intraocular lenses: materials and methods
نویسنده
چکیده
منابع مشابه
Biocompatibility of Intraocular Lenses
The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens. The factor indicating the biocompatibility of an intraocular lens is the behavior of inflammatory and lens epithelial cells. Hence, the biocompatibility of intraocular lens materials is assessed in...
متن کاملکاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار
Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...
متن کاملPosterior Capsule Opacification and Nd-YAG rates evaluation in a large series of pseudophakic cases
Purpose To evaluate the influence of Intraocular Lens (IOL) material and design on Posterior Capsule Opacification (PCO) and Neodymium-YAG (Nd-YAG) rates in eyes implanted with different Posterior Chamber Intraocular Lenses (PC IOLs) designs at the end of uncomplicated cataract surgeries. Setting Oculus Eye Clinic, Bucharest, Romania. Design Retrospective, observational study. Methods Thi...
متن کاملنتایج درازمدت نصب اسکلرال لنزهای داخل چشمی جابجا شده به روش خارج کردن هاپتیک از برش کوچک قرنیه
Background & Aim: Several methods have been reported for refixation of dislocated intraocular lenses (IOLs). However, these methods are associated with some disadvantages including vitreous prolaps, vitreous traction, ocular collapse, intraocular hemorrhage, high astigmatism, and the need for complex intraocular maneuvers. The aim of this study was to evaluate the results of transscleral fi...
متن کاملScanning electron microscopic characteristics of phakic intraocular lenses.
OBJECTIVE To analyze the surface quality of new generation phakic intraocular lenses (IOLs). DESIGN Experimental materials study. MATERIALS Three different new generation phakic IOLs: angle-fixated anterior chamber lens Chiron Vision NuVita MA20 (polymethylmethacrylate [PMMAD, iris-fixated anterior chamber lens Ophtec Artisan Iris-Claw (PMMA), posterior chamber lens Staar ICM (polymer from ...
متن کامل