Evaluation of patient exposure with Flat Panel Detector (FPD) in X-ray TV system
نویسندگان
چکیده
The use of flat-panel detector (FPD) systems in TV equipment for gastrointestinal tract examination is increasing. The use of FPD systems is believed to reduce the exposure dose. When our institution changed its TV equipment from an image intensifier (GE;MS90Tj) system to an FPD (Shimadzu;SONIALVISION safire DAR-3500) system, we measured the doses produced and carried out a comparative examination of the extent to which exposure could be reduced. Two TV systems were used. We used an analyzer to measure output waveform, tube voltage, and half-value layer (HVL), and an ionization chamber dosimeter to carry out dose-in-air measurements. Body thickness, number of image acquisitions, and fluoroscopy time are required for the calculation of entrance skin dose (ESD). We therefore measured body thicknesses in 1000 upper gastrointestinal tract (UGI) and barium enemas and obtained average body thicknesses for males and females by age group. Values used for number of image acquisitions and fluoroscopy times were the averages in our institution over a two-year period. When an I.I. system was used, the average ESD during UGI examination were 126.8 mGy fluoroscopy dose and 11.62 mGy imaging dose, for an average total dose of 138.42 mGy per examination. ESD during barium enema averaged 201.73 mGy fluoroscopy dose and 45.2 mGy imaging dose, for an average total dose of 246.92 mGy per examination. When an FPD system was used, the average ESD during UGI examination were 58.71 mGy fluoroscopy dose and 5.72 mGy imaging dose, for an average total dose of 64.43 mGy per examination. ESD during barium enema averaged 112.21 mGy fluoroscopy dose and 24.55 mGy imaging dose, for an average total dose of 136.76 mGy per examination. The use of an FPD system reduced both fluoroscopy dose and imaging dose by 50%. The number of TV systems equipped with FPD in Japan has increased from around 1300 in 2006 to around 1700 in 2007. The use of FPD systems can be expected to increase in future. This will enable major reductions in patient exposure dose. Keywords; FPD, patient exposure, UGI examination, barium enema examination
منابع مشابه
Reduction of radiation dose for cerebral angiography using flat panel detector of direct conversion type: a vascular phantom study.
BACKGROUND AND PURPOSE Compared with image intensifier television (I.I.-TV) system, an angiography system using the flat panel detector (FPD) of direct conversion type has a high spatial resolution, which may improve image quality, reduce patient exposure, or both. Our purpose was to evaluate the detection of simulated aneurysmal blebs under dose reduction with the FPD system in comparison with...
متن کاملRAD Exposure Dose to Neonates , Operators and Attendants Using MobileDaRt Evolution
It is well known that chest X-ray imaging plays a very important role in the diagnosis of chest lesions in neonates 1) . However, concerns exist that the exposure of neonatal patients to increasing quantities of radiation through imaging will increase the future risk of cancer development. Additionally, the exposure dose received by the operator and attendants is also of concern, as they often ...
متن کاملAbstractID: 14240 Title: Efficacy of a linear lag correction algorithm in an a-Si flat-panel x-ray detector
ID: 14240 Title: Efficacy of a linear lag correction algorithm in an a-Si flat-panel x-ray detector Purpose: Lag in a-Si flat-panel detectors (FPD) causes significant artifact. To date, most correction models have assumed a linear, time-invariant model (LTIM). We investigated detector response as a function of incident exposure. Method and Materials: The physics theory for charge trapping in FP...
متن کاملDevelopment of a cardiac evaluation method using a dynamic flat-panel detector (FPD) system: a feasibility study using a cardiac motion phantom.
The purpose of this study is to investigate the feasibility of cardiac evaluation with a dynamic flat-panel detector (FPD), based on changes in pixel values during cardiac pumping. To investigate the feasibility of cardiac evaluation with a dynamic flat-panel detector (FPD), based on changes in pixel values during cardiac pumping. Sequential radiographs of a cardiac motion phantom and water-equ...
متن کامل3D digital subtraction angiography of intracranial aneurysms: comparison of flat panel detector with conventional image intensifier TV system using a vascular phantom.
BACKGROUND AND PURPOSE Compared with the image intensifier (I.I.)-TV system, the flat panel detector (FPD) system of direct conversion type has several theoretic advantages, such as higher spatial resolution, wide dynamic range, and no image distortion. The purpose of this study was to compare the image quality of 3D digital subtraction angiography (DSA) in the FPD and conventional I.I.-TV syst...