Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

نویسندگان

  • Jue Cao
  • Kagan Ozer
چکیده

BACKGROUND Volar locking plates provide significant structural stability to the distal radius. Failure of a volar locked plating is a rarely reported complication in the literature. CASE PRESENTATION A 40 year-old, obese female patient who presented with a displaced extraarticular distal radius fracture, underwent open reduction and internal fixation of the fracture using a volar locking plate. Radiographs taken at 10 weeks postoperatively showed failure of fixation with breakage of the four distal locking screws. A hardware removal was performed at 6 months, and the patient was then lost to follow-up. She presented again at 18 months after the first surgery, with significant pain, and radiographic signs of a radial collapse and a fracture-nonunion. A total wrist fusion was performed as the method of choice at that point in time. CONCLUSION Volar locked plating represents the new "gold standard" of distal radius fracture fixation. However, despite the stability provided by locking plates, hardware failure may occur and lead to a cascade of complications which will ultimately require a wrist fusion, as outlined in this case report. Additional structural support by bone grafting may be needed in selected cases of volar locked plating, particularly in patients with a high risk of developing a fracture-nonunion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...

متن کامل

Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis

Objective: The superiority of volar locking plate fixation and K-wire fixation on treatment of distal radius fractures was controversial. Thus, we performed a meta-analysis to compare the efficacy of volar locking plate and K-wires for distal radius fracture. Methods: We searched Embase, Medline and PubMed for randomized controlled trials which compare the effects of volar locking plate and K-w...

متن کامل

Successful closed reduction of refractured wrist with a bent volar distal radius plate.

A case is presented of a 78-year-old woman who sustained a re-fracture of the distal radius after initial fixation with a volar locking plate. The fracture was located in the mid-portion of the volar plate with palmar apex bending of the plate and signs of median nerve compression. A successful closed reduction was performed without hardware failure. The fracture united uneventfully.

متن کامل

Volar Locking Plate Breakage after Nonunion of a Distal Radius Osteotomy

We report a 38-year-old male with a nonunion followed by plate breakage after volar plating of a distal radius osteotomy. Volar locking plates have added a new approach to the treatment of distal radius malunions, due to a lower morbidity of the surgical approach and the strength of the final construction, allowing early mobilization and return to function. Conclusion. Plate breakage is an unco...

متن کامل

CASE REPORT Union of an intra-articular distal radius fracture after successive failures of three locking plates: a case report

We report a case of a 30-year old male, who presented with a right distal radius intra-articular fracture complicated by compartment syndrome. He was treated with fasciotomies and fracture fixation with a 3.5 mm LCP (Synthes TM ), followed 7 days later by skin graft. Repeat radiographs 8 weeks later showed a break across the plate at the level of an unfilled screw hole over the fracture. He und...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -