Instability of 24-hour intraocular pressure fluctuation in healthy young subjects: a prospective, cross-sectional study
نویسندگان
چکیده
BACKGROUND Elevated intraocular pressure (IOP) is a major risk factor for the development and/or progression of glaucoma, and a large diurnal IOP fluctuation has been identified as an independent risk factor of glaucoma progression. However, most previous studies have not considered the repeatability of 24-hour IOP measurements. The aim of this study was to evaluate the instability of 24-hour IOP fluctuations in healthy young subjects. METHODS Ten healthy young volunteers participated in this prospective, cross-sectional study. Each subject underwent 24-hour IOP and systolic/diastolic blood pressure (SBP/DBP) assessments both in sitting and supine positions every 3 hours, once a week for 5 consecutive weeks. Mean ocular perfusion pressure (MOPP) was then calculated for both positions. The intraclass correlation coefficients (ICCs) of maximum, minimum, and fluctuation parameters were computed for IOP, SBP/DBP, and MOPP. Fluctuation was defined as the difference between maximum and minimum values during a day. RESULTS Among the serial measurements taken over a 24-hour rhythm, the maximum/minimum values of IOP, as well as BP, showed excellent agreement: regardless of position, all ICC values were over 0.800. Most of the BP fluctuation values also showed excellent agreement. IOP fluctuation, however, did not show excellent agreement; the ICC of sitting IOP fluctuation was just 0.212. MOPP fluctuation also showed poor agreement, especially in the sitting position (ICC, 0.003). CONCLUSION On a day to day basis, 24-hour IOP fluctuations were not highly reproducible in healthy young volunteers. Our results imply that a single 24-hour IOP assessment may not be a sufficient or suitable way to characterize circadian IOP fluctuations for individual subjects.
منابع مشابه
Author's response to reviews Title:Instability of 24-Hour Intraocular Pressure Fluctuation in Healthy Young Subjects: a prospective, cross-sectional study Authors:
Author's response to reviews: Our manuscript was edited as recommended. Please see the attached certification. We appreicate your careful consideration.
متن کاملThe circadian curve of intraocular pressure: can we estimate its characteristics during office hours?
PURPOSE To verify whether office-hour measurements in patients in different body positions can estimate the characteristics of 24-hour intraocular pressure (IOP). METHODS The 24-hour IOP curves of 29 healthy subjects (10 young adults, 19 elderly) and 30 patients with untreated glaucoma were analyzed. Measurements were taken at 9 AM; 12, 3, 6, and 9 PM; and 12, 3, and 6 AM, both in the supine ...
متن کاملIncreased 24-hour variation of human intraocular pressure with short axial length.
PURPOSE To characterize 24-hour variation of intraocular pressure (IOP) in healthy young adults based on the axial length of the eye. METHODS Twenty-four-hour IOP data were collected from nine healthy young adults with hyperopia, age range 18 to 25 years, in a sleep laboratory. Every 2 hours, measurements of IOP were taken in the participants after 5 minutes in the supine position and 5 minut...
متن کاملDiurnal Intraocular Pressure Fluctuation in Eyes with Angle-closure
PURPOSE To investigate diurnal intraocular pressure (IOP) fluctuation in eyes with angle-closure. MATERIALS AND METHODS Seventy-seven eyes of 77 newly diagnosed patients with angle closure [33 subjects with primary angle-closure suspects (PACS), 23 subjects with primary angle-closure (PAC), and 21 subjects with primary angle-closure glau-coma (PACG)] were enrolled after laser peripheral irido...
متن کامل24-hour intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor.
IMPORTANCE This study evaluates a new device that has been proposed to continuously monitor intraocular pressure (IOP) over 24 hours. OBJECTIVE To evaluate 24-hour IOP rhythm reproducibility during repeated continuous 24-hour IOP monitoring with noncontact tonometry (NCT) and a contact lens sensor (CLS) in healthy participants. DESIGN, SETTING, AND PARTICIPANTS Cross-sectional study of 12 y...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2014