Concomitant gradient field effects in spiral scans.
نویسندگان
چکیده
Maxwell's equations imply that imaging gradients are accompanied by higher order spatially varying fields (concomitant fields) that can cause artifacts in MR imaging. The lowest order concomitant fields depend quadratically on the imaging gradient amplitude and inversely on the static field strength. Time-varying concomitant fields that accompany the readout gradients of spiral scans cause unwanted phase accumulation during the readout, resulting in spatially dependent blurring. Concomitant field phase errors are independent of echo time and, therefore, cannot be detected using Dixon-type field map measurements that are normally used to deblur spiral scan images. Data acquisition methods that reduce concomitant field blurring increase off-resonant spin blurring, and vice versa. Blurring caused by concomitant fields can be removed by variations of image reconstruction methods developed to correct for spatially dependent resonance offsets with nonrectangular k-space trajectories.
منابع مشابه
Fast Concomitant Gradient Field Correction for Spiral Scans
Introduction: A major drawback to non-Cartesian imaging is the off-resonance blurring effects. Common linear techniques that remove the distortion effects are not sufficient, because the high order concomitant gradient fields are nontrivial for low fields and for scans that are more than 5 cm off isocenter [1]. Previous correction algorithms either are slow or do not take into account the known...
متن کاملFast Field Inhomogeneity and Concomitant Gradient Field Correction in Spiral Cardiac Imaging
Introduction: Cardiac imaging, for both real-time and triggered imaging, requires a high data acquisition rate. Spiral trajectories achieve this rate; however, their advantages are shadowed by off-resonance blurring and distortion effects. Current techniques to correct for this image degradation do not easily or quickly account for the different effects specifically field inhomogeneities and co...
متن کاملFast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradients.
Off-resonance effects can cause image blurring in spiral scanning and various forms of image degradation in other MRI methods. Off-resonance effects can be caused by both B0 inhomogeneity and concomitant gradient fields. Previously developed off-resonance correction methods focus on the correction of a single source of off-resonance. This work introduces a computationally efficient method of co...
متن کاملSingle-Shot Diffusion-Weighted Spiral Imaging
Introduction: Spiral trajectories offer a range of desirable properties: short echo times, high SNR efficiency, a uniform point-spread function and a well-conditioned reconstruction problem for high reduction factors in parallel imaging, such as with circular coil-arrays as employed for head MRI. In diffusion weighted MRI (DWI), single-shot spiral imaging could increase the achievable SNR while...
متن کاملSpiral imaging: a critical appraisal.
In view of recent applications in cardiovascular and functional brain imaging, this work revisits the basic performance characteristics of spiral imaging in direct comparison to echo-planar imaging (EPI) and conventional rapid gradient-echo imaging. Using both computer simulations and experiments on phantoms and human subjects at 2.9 T, the study emphasizes single-shot applications and addresse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 41 1 شماره
صفحات -
تاریخ انتشار 1999