Analysis of HRT images: comparison of reference planes.

نویسندگان

  • Alessandro Poli
  • Nicholas G Strouthidis
  • Tuan A Ho
  • David F Garway-Heath
چکیده

PURPOSE The values of Heidelberg Retinal Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) stereometric parameters depend on the reference plane (RP), the instability of which results in parameter variability. Identification of change depends on RP stability. This study was undertaken to evaluate the influence of various RPs on rim areas (RAs) in a longitudinal image series. METHODS A longitudinal image series of 31 subjects with ocular hypertension who had reproducible visual field loss and 19 normal subjects was analyzed using five different RPs: the standard RP (HRT software version 3.1.2.0), two 320-mum RPs (software ver. 3.1.2.0 and 1.7.0), a previously described experimental RP, and a new Moorfields RP. The Moorfields RP takes the standard RP at baseline and then is fixed relative to the reference ring for subsequent images. Linear regression of RA over time was performed, and the slope and residual SD (RSD) were calculated for each RP. Comparisons between RPs were made by paired t-tests. RESULTS In eyes with progressing disease, application of the standard RP resulted in significantly greater variability (as measured by the RSD) compared with other RPs (mean 0.057 mm(2) vs. 0.035-0.038 mm(2)). There was a trend toward faster RA change/time (mean, -0.0123 mm(2)/y) for the standard RP and slower (-0.0095 mm(2)/y) for the experimental RP. There was a trend for the Moorfields RP to result in the best signal-to-noise ratio (speed of RA change/variability): mean RA slope -0.0118 mm(2)/y and mean global RSD 0.037mm(2). CONCLUSIONS Compared to the standard RP, the Moorfields RP has significantly lower variability and probably provides a greater facility for discriminating RA change from measurement variability in a longitudinal HRT image series.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SCIENTIFIC REPORT Improving the repeatability of Heidelberg retina tomograph and Heidelberg retina tomograph II rim area measurements

Aims: To devise and test strategies for improving Heidelberg retina tomograph (HRT and HRT-II) rim area (RA) repeatability and assess the benefit of the strategies in time series of HRT images. Methods: The effect of the standard and 320 mm reference planes and image quality on RA repeatability was assessed in a test-retest HRT image dataset from 74 subjects. A longitudinal HRT image dataset fr...

متن کامل

Improving the repeatability of Heidelberg retina tomograph and Heidelberg retina tomograph II rim area measurements.

AIMS To devise and test strategies for improving Heidelberg retina tomograph (HRT and HRT-II) rim area (RA) repeatability and assess the benefit of the strategies in time series of HRT images. METHODS The effect of the standard and 320 microm reference planes and image quality on RA repeatability was assessed in a test-retest HRT image dataset from 74 subjects. A longitudinal HRT image datase...

متن کامل

Inter- and intraobserver variation in the analysis of optic disc images: comparison of the Heidelberg retina tomograph and computer assisted planimetry.

AIMS The development of imaging and measurement techniques has brought the prospect of greater objectivity in the measurement of optic disc features, and therefore better agreement between observers. The purpose of this study was to quantify and compare the variation between observers using two measurement devices. METHODS Optic disc photographs and images from the Heidelberg retina tomograph...

متن کامل

Comparison of Neuroretinal Rim Area Measurements Made by the Heidelberg Retina Tomograph I and the Heidelberg Retina Tomograph II

PURPOSE To investigate the agreement between neuroretinal rim area (RA) measurements using the Heidelberg Retina Tomograph I (HRT Classic) and Heidelberg Retina Tomograph II (HRT II). To compare apparent RA changes in follow-up series of HRT II topographies when using either an HRT Classic or HRT II mean topography as baseline. DESIGN Cross-sectional study and "no-change," short time series s...

متن کامل

Impulsive Noise Elimination Considering the Bit Planes Information of the Image

Impulsive noise is one of the imposed defectives degrades the quality of images. Performance of many image processing applications directly depends on the quality of the input image. Hence, it is necessary to de-noise the degraded images without losing their valuable information such as edges. In this paper we propose a method to remove impulsive noise from color images without damaging the ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 49 9  شماره 

صفحات  -

تاریخ انتشار 2008