Beam Selection in Radiotherapy Design
نویسندگان
چکیده
The optimal design of a radiotherapy treatment depends on the collection of directions from which radiation is focused on the patient. These directions are manually selected by a physician and are typically based on the physician’s previous experiences. Once the angles are chosen, there are numerous optimization models that decide a fluency pattern (exposure times) that best treats a patient. So, while optimization techniques are often used to decide the length of time a patient is exposed to a high-energy particle beam, the directions themselves are not optimized. The problem with optimally selecting directions is that the underlying mixed integer models are well beyond our current solution capability. We present a rigorous mathematical development of the beam selection problem that provides a unified framework for the problem of selecting beam directions. This presentation provides insights into the techniques suggested in the literature and highlights the difficulty of the problem. We also compare several techniques head-to-head on clinically relevant, two-dimensional problems.
منابع مشابه
Optimization of Beam Orientation and Weight in Radiotherapy Treatment Planning using a Genetic Algorithm
Introduction: The selection of suitable beam angles and weights in external-beam radiotherapy is at present generally based upon the experience of the planner. Therefore, automated selection of beam angles and weights in forward-planned radiotherapy will be beneficial. Material and Methods: In this work, an efficient method is presented within the MATLAB environment to investigate how to improv...
متن کاملComparing Beam Selection Strategies in Radiotherapy Treatment Design: The Influence of Dose Point Resolution
The design of a radiotherapy treatment includes the selection of beam angles (geometry problem), the computation of a fluence pattern for each selected beam angle (intensity problem), and finding a sequence of configurations of a multilef collimator to deliver the treatment (realization problem). While many mathematical optimization models and algorithms have been proposed for the intensity pro...
متن کاملThe Influence of Dose Grid Resolution on Beam Selection Strategies in Radiotherapy Treatment Design
The design of a radiotherapy treatment includes the selection of beam angles (geometry problem), the computation of a fluence pattern for each selected beam angle (intensity problem), and finding a sequence of configurations of a multilef collimator to deliver the treatment (realization problem). While many mathematical optimization models and algorithms have been proposed for the intensity pro...
متن کاملInfluence of Compensator Thickness and Field Size on Buildup factor of a Brass Compensator for Intensity- Modulated Radiation Therapy
Introduction: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as...
متن کاملAn Update of Couch Effect on the Attenuation of Megavoltage Radiotherapy Beam and the Variation of Absorbed Dose in the Build-up Region
Purpose: Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch.Materials and Methods: In this study, we ...
متن کامل