An instrumented bone/soft tissue phantom designed to mimic HIFU treatments of bone
نویسندگان
چکیده
Background/introduction Clinically, HIFU exposures of bone are used to palliate pain from primary or secondary bone tumours. Such tumours weaken bone structure and render the patient susceptible to bone fracture. Ultrasound metrology for bone exposures is extremely challenging. The ultrasound beam is strongly reflected at the bone surface, with rapid surface absorption of sound entering the cortex. Pain relief is obtained when the HIFU induced temperature increase ablates the peri-osteal nerves. Standard PRF based MR thermometry, used for treatment monitoring, is inappropriate for bone. Thus, a method of determining the temperature distribution in a clinical environment is needed.
منابع مشابه
Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...
متن کاملSimulating temperature distribution of high-intensity focused ultrasound during bone treatments
Background/introduction To help improve therapeutic results for treatment of bone tumors, high intensity focused ultrasound (HIFU) is being investigated as a non-invasive alternative to surgery and radiotherapy. HIFU ablative treatments require an imaging modality for guidance, and magnetic resonance (MR) imaging is currently the strongest choice as it is able to provide temperature mapping thr...
متن کاملEffects of magnetic resonance-guided high-intensity focused ultrasound ablation on bone mechanical properties and modeling
BACKGROUND Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a promising technique for palliative treatment of bone pain. In this study, the effects of MR-HIFU ablation on bone mechanics and modeling were investigated. METHODS A total of 12 healthy rat femurs were ablated using 10 W for 46 ± 4 s per sonication with 4 sonications for each femur. At 7 days after treatment...
متن کاملStudying dose equivalents of radio-sensitive organs in head and neck region during nasopharynx proton therapy using Monte Carlo MCNPX code
In the present work, dose equivalents of radiosensitive organs in head and neck region have been calculated during nasopharynx proton therapy. For this purpose, a middle-size tumor was designed with the use of clinical information, and was then incorporated into the adult male ICRP phantom. According to the medical data, eight radiation paths around the neck were selected. After that, appropria...
متن کاملSafety limitations of MR‐HIFU treatment near interfaces: a phantom validation
Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a noninvasive image-guided technique used to thermally ablate solid tumors. During treatment, ultrasound reflections from distal media interfaces can shift prescribed treatment locations. The purpose of this study was to investigate the effect of normal incidence reflections from air, acrylic (modeling bone), and rubber on...