Monitoring of platinum surface contamination in seven Dutch hospital pharmacies using inductively coupled plasma mass spectrometry
نویسندگان
چکیده
OBJECTIVE To develop, validate, and apply a method for the determination of platinum contamination, originating from cisplatinum, oxaliplatinum, and carboplatinum. METHODS Inductively coupled plasma mass spectrometry (ICP-MS) was used to determine platinum in wipe samples. The sampling procedure and the analytical conditions were optimised and the assay was validated. The method was applied to measure surface contamination in seven Dutch hospital pharmacies. RESULTS The developed method allowed reproducible quantification of 0.50 ng l(-1) platinum (5 pg/wipe sample). Recoveries for stainless steel and linoleum surfaces ranged between 50.4 and 81.4% for the different platinum compounds tested. Platinum contamination was reported in 88% of the wipe samples. Although a substantial variation in surface contamination of the pharmacies was noticed, in most pharmacies, the laminar-airflow (LAF) hoods, the floor in front of the LAF hoods, door handles, and handles of service hatches showed positive results. This demonstrates that contamination is spread throughout the preparation rooms. CONCLUSION We developed and validated an ultra sensitive and reliable ICP-MS method for the determination of platinum in surface samples. Surface contamination with platinum was observed in all hospital pharmacies sampled. The interpretation of these results is, however, complicated.
منابع مشابه
Evaluation of the risk of contamination of surgical personnel by vaporization of oxaliplatin during the intraoperative hyperthermic intraperitoneal chemotherapy (HIPEC).
AIMS To evaluate if oxaliplatin is likely to vaporize under HIPEC conditions and to see if it could be a source of pulmonary contamination for surgeons. METHODS Three oxaliplatin concentrations (230, 460 and 920 mg oxaliplatin/l), 3 heating temperatures (41, 43 and 45 degrees C) and 3 bubbling durations (30, 60 and 90 min) were tested. Drug vaporization was evaluated by using inductively coup...
متن کاملThe role of surface geochemistry in the discovery of the Babel and Nebo magmatic nickel–copper–PGE deposits
The inexpensive geochemical exploration technique based on broadspaced deflation lag sampling played a key role in the discovery of the Babel and Nebo ortho-magmatic Ni–Cu–platinum group elements (PGE) deposits. An area of 1100 km in the western Musgrave Block in central Australia was explored using deflation lag samples collected on a 1 km 0.5 km grid. A total of 35 elements were determined us...
متن کاملScreening and Optimization of Microextraction of Pb(II) by Inductively Coupled Plasma-Atomic Emission Using Response Surface Methodology
Dispersive liquid–liquid microextraction (DLLME) combined with inductively coupled plasma-atomic emission spectrometry (ICP-AES) was applied for the determination of lead in different environmental water samples. Ammonium pyrrolidine dithiocarbamate (APDC), chloroform and ethanol were used as chelating agent, extraction solvent and disperser solvent, respectively. The effective parameters, such...
متن کاملDetermination of platinum originating from carboplatin in canine sebum and cerumen by inductively coupled plasma mass spectrometry.
We present highly sensitive, reliable methods for the determination of platinum originating from carboplatin in canine sebum and cerumen. The methods are based on the measurement of platinum by inductively coupled plasma mass spectrometry and allow quantification of 0.15 pg platinum per cm² body surface in canine sebum and of 7.50 pg platinum per sampled ear canal. The sample pretreatment proce...
متن کاملPharmacokinetics and tissue distribution of novel platinum containing anticancer agent BP-C1 studied in rabbits using sector field inductively coupled plasma mass spectrometry.
A method of platinum quantification in whole blood samples after microwave digestion using sector field inductively coupled plasma mass spectrometry has been developed. The following analytical figures of merit have been established: limit of detection 1.1 µg/L for blood samples, dynamic range 3.6-200 µg/L, intra-day precision (relative standard deviation, n = 9) did not exceed 5%. Spiked sampl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International Archives of Occupational and Environmental Health
دوره 80 شماره
صفحات -
تاریخ انتشار 2007