Retinal blood flow evaluation.

نویسندگان

  • Constantin J Pournaras
  • Charles E Riva
چکیده

Much of our basic knowledge of retinal blood flow regulation is based on data obtained from animal experiments through the use of invasive techniques. However, during the last decades, major developments in the field of optics and lasers have led to a variety of noninvasive techniques, which have been applied to the human eye for the investigation of retinal hemodynamics, and more specifically the regulation of retinal blood flow in response to a number of physiological and pharmacological stimuli. The Retinal Vessel Analyzer has markedly simplified the measurement of the diameter of retinal vessels, as well as the change in this diameter evoked by various physiological stimuli (dynamic measurements). Bidirectional laser Doppler velocimetry allows the measurement of absolute red blood cell centerline velocity, which, when combined with the diameter allows the calculation of retinal blood flow in the main retinal vessels. Laser Doppler flowmetry and laser speckle flowgraphy are techniques that measure the velocities of blood in discrete areas of the retinal tissue microcirculation. Adding a scanning capability, a spatial map of velocities across the retinal tissue is obtained. The blue-field simulation technique allows the quantification of the velocity, number and velocity pulsatility of leukocytes moving in the retinal capillaries of the macular region. With color Doppler imaging, the peak systolic and end-diastolic values of blood velocity in the ophthalmic and central retinal artery are measured, from which a resistivity index is obtained. These techniques may help better understand the role of altered retinal blood flow and its regulation in the pathogenesis of retinal diseases of vascular origin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic full field analysis of perfusion images gained by scanning laser Doppler flowmetry.

BACKGROUND Scanning laser Doppler flowmetry (SLDF) enables the measurement of the laser Doppler frequency shift in retinal tissue. This process allows the quantification of retinal and optic nerve head perfusion in an area of 2.7 mm x 0.7 mm within 2 seconds and with a spatial resolution of 10 microns x 10 microns. Owing to the local heterogeneity of the retinal microcirculation itself and to h...

متن کامل

Optical microangiography of retina and choroid and measurement of total retinal blood flow in mice

We present a novel application of optical microangiography (OMAG) imaging technique for visualization of depth-resolved vascular network within retina and choroid as well as measurement of total retinal blood flow in mice. A fast speed spectral domain OCT imaging system at 820nm with a line scan rate of 140 kHz was developed to image the posterior segment of eyes in mice. By applying an OMAG al...

متن کامل

Limitations of color Doppler sonography in the imaging of ocular vessels.

PURPOSE To describe a case where detection of blood flow in the central retinal artery and the central retinal vein was limited by an artifact evoked by the optic disc drusen. METHODS Case report. RESULTS During color Doppler sonography, examination of optic disc drusen may generate an artifact--the so-called twinkling artifact--which can simulate blood flow and make evaluation of the central...

متن کامل

Retinal blood flow autoregulation after dynamic exercise in healthy young subjects.

PURPOSE To evaluate the retinal blood flow before and after the increase in systemic blood pressure to assess the autoregulation in healthy young subjects. METHODS Twenty eyes of 20 healthy volunteers were examined. The retinal blood flow was assessed by a Heidelberg retina flowmeter (HRF), while the systemic pressure was assessed by a portable electronic sphygmomanometer. Furthermore intraoc...

متن کامل

Two dimensional mapping of the perfusion of the retina and optic nerve head.

AIM To present a new non-invasive method of performing a high definition topography of perfused vessels of the retina and the optic nerve head with simultaneous evaluation of blood flow. METHOD By a combination of a laser Doppler flowmeter with a scanning laser system the perfusion of the retina and the optic nerve head is visualised. The principles of measuring blood flow by laser Doppler fl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmologica. Journal international d'ophtalmologie. International journal of ophthalmology. Zeitschrift fur Augenheilkunde

دوره 229 2  شماره 

صفحات  -

تاریخ انتشار 2013