Polygonizing skeletal sheets of CT-scanned objects by partitioin of unity approximations
نویسندگان
چکیده
The skeletal structures of solid objects play an important role in medical and industrial applications. Given a volumetrically sampled solid object, our method extracts a nice-looking skeletal structure represented as a polygon mesh. The purpose is to achieve a noise-robust extraction of the skeletal mesh from a real-world object obtained using a scanning technology such as the CT scan method. We first approximate the input through a set of spherically supported polynomials that provide an adaptively smoothed intensity field, and then perform a polygonization process to find the extremal sheet of the field, which is regarded as a skeletal sheet in this research. In our polygonization, a subset of the weighted Delaunay tetrahedrization defined by a set of spherical supports is used as an adaptively sampled grid. The derivatives for detecting extremality are analytically evaluated at the tetrahedron vertices. We also demonstrate the effectiveness of our method by extracting skeletal meshes from noisy CT images.
منابع مشابه
Polygonizing Non-Uniformly Distributed 3D Points by Advancing Mesh Frontiers
3D digitization devices produce very large sets of 3D points sampled from the surfaces of the objects being scanned. A mesh construction procedure needs to be applied to derive polygon mesh from the 3D point sets. As the 3D points derived from digitization devices based on digital imaging technologies are inherently non-uniformly distributed over regions that may contain surface discontinuities...
متن کاملImage Optimization and reduction of radiation dose in CT of the paranasal sinuses
Introduction: Since demand for computed tomography (CT) examinations is growing, patients are exposed more frequently to ionizing radiation. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. Present study aimed to optimize and reduce radiation dose in a CT of the paranasal si...
متن کاملThe Iinterpretative Analysis of Verse 213 of Chapter Bagherah in Fariqain (Sunni and Shia) Interpretations
The issue of the unity and difference of humans is rooted in the history of man’s social life, and this is the basis for the emergence of divine prophets and the revelation of the heavenly books. With a brief overview of this issue, Verse 213 of chapter Bagherah explains the evolution of human thought in different stages. There are many ambiguities about the nature of the basis of unity, the ca...
متن کاملSports activity done five days before PET/CT results in augmented FDG uptake in skeletal muscles
Increased metabolic activity in muscle secondary to excessive muscle activity during the uptake phase and shortly before FDG injection is a known phenomenon. We present FDG PET/CT findings in a young male, known case of carcinoma maxilla His scan showed diffuse increased metabolic activity in multiple skeletal muscle groups. There was history of unaccustomed, strenuous sports activity of skiing...
متن کاملDiagnostic dilemma of ectopic pelvic kidney in planar skeletal and renal cortical scintigraphy resolved by SPECT/CT
We present a 55-year old male patient who was subjected to whole body skeletal scintigraphy for metastatic work up of urinary bladder cancer. Whole body 99mTc-methylene diphosphonate (MDP) skeletal scintigraphy was performed. That revealed no skeletal metastasis in the entire body skeleton and normally visualized left kidney with empty right renal fossa. Additionally tracer activity ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008