The problem of secondary contamination following chemical agent release

نویسنده

  • David Baker
چکیده

In the present issue of Critical Care, an article by Okumura and colleagues has been published on the problem of secondary contamination following chemical agent release [1]. The authors' draw on first-hand experience [2–5] of the secondary contamination experienced during the Tokyo sarin release in 1995. This experience is important, both for the care of contaminated patients and for the safety of medical staff. The Tokyo terrorist attack in 1995 involved the release of the nerve agent sarin, which produced nearly 1500 casualties but only 12 fatalities. The low number of fatalities may have been due to the impure nature of the sarin used, but these figures underline the fact that chemical agent release does not necessarily produce the mass fatalities suggested by the term 'weapons of mass destruction'. The large number of casualties from the terrorist attack and the analysis of secondary contamination casualties from the transmission of sarin gas formed a significant proportion of the injured in Japan. Of the responding fire workers (who are professionally familiar with the management of released hazardous materials) 9.9% suffered secondary contamination, while the rate among medical personnel at St Luke's hospital (where most of the casualties were received) was 23%. The authors note that the rate of secondary exposure by occupation was 39.3% among nurse assistants, was 26.5% among nurses, was 25.5% among volunteers, was 21.8% among doctors, and was 18.2% among clerks, indicating that the degree of secondary contamination rose in proportion to the length of time a medical worker may have spent in contact with an undecontaminated patient. The data presented by the authors underline the need for awareness, particularly among medical responders, of personal protection (cross-contamination?) and methods of decontamination. Monitoring of secondary contamination and the level of protection required by medical staff are a matter of continuing debate. The authors express concern about the use of level C protection (comprising a lightweight agent-proof suit and a filtration respirator) and recommend that level B protection (a heavier suit with a self-contained air supply) should be used by medical responders. Readers should be aware that this view is not generally accepted in the international medical community where level C protection is regarded as being the standard for healthcare workers involved in toxic releases [6,7], allowing them to provide essential emergency medical care inside a contaminated area. Level B protection has inherent dangers for the wearer and these should be …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Bio-Oxidation Energy Released by Thermophiles in Secondary and Mixed Bio-Solids

Reaction constants and heat release during thermophilic aerobic digestion of typical secondary and mixed sludges were determined. Maximum reaction constant, determined by measuring the amounts of biodegradable volatile suspended solids (bVSS) removed, occurred in the temperature range of 55-60 ºC. Measurement of heat releases were carried out, at the same range, by the aid of a temperature ...

متن کامل

Evaluation of Microleakage in Fissure Sealants following Contamination with Artificial Saliva at Different Curing Times with or without using bonding agent

Background and Aim: One of the important factors in microleakage of fissure sealants is saliva contamination. Researchers believe that applying bonding agents can reduce the microleakage. The present study compared the microleakage of a fissure sealant contaminated with artificial saliva at different curing times with or without using a bonding agent. Materials and Methods: In this in-vitro ...

متن کامل

Influence of Formulation Parameters on the Release of Diclofenace Sodium from Matrices with Manufacturing Formulation Ingredients

Effects of formulation parameters on the fractional release profile of diclofenac sodium from matrices having the manufacturing formulation ingredients are studied. As a content of cetyl alcohol (rate controlling agent) in the matrix increases, the fractional release decreases. The fractional release increases either by increasing sucrose content outside the granule or by decreasing sucrose...

متن کامل

Sodium Alginate/Starch Blends Loaded with Ciprofloxacin Hydrochloride as a Floating Drug Delivery System - In Vitro Evaluation

In the present study, Floating Drug Delivery Beads (FDDS) were prepared with sodium alginate/ starch blend as a matrix, sodium hydrogen carbonate as a pore forming agent, methyl cellulose as a binder and barium chloride solution as a hardening agent. In order to prepare the beads with different porosity and morphology the ratio between pore forming agent to polymer blend and ratio of the co...

متن کامل

Study on Chemical Contamination Problem in Macaroni and Pasta Production Technology

Current study was done to determine the concentration of heavy metals including Lead and Cadmium and nutrients element Copper and Zinc in a simple and whole wheat Macaroni in the valid different supermarkets in the city of Tehran. 254 samples from seven Iranian simple Macaroni , four foreign simple Macaroni and two Iranian whole wheat macaroni were purchased consecutively in 3 seasons of 2015. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2005