The "Passivhaus" standard has become a set of rules and suggestions that allow any architect or engineer to design a house with very low or zero energy consumption. The simple application of the "Passivhaus" building code does not necessarily mean that the expected comfort conditions will be achieved, since the rules were first developed in colder climates, which are very different from the Mediterranean climate typical of large areas of the Italian territory. This paper aims at studying the potential critical issues of the "Passivhaus" standard when applied in Mediterranean and Southern European climatic zones, where the summer cooling demand is as important as winter heating one. In this paper, a single family, two floors passive house with a defined size and shape was designed and studied in three different Italian cities (Rome, Palermo and Bologna) characterized by different climatic zones, with the aim of evaluating the energy performance in winter and summer. From the results of this study it was possible to show that passive buildings internal comfort can be controlled and optimized by controlling the ventilation rate, with a minimal utilization of heating and cooling systems. Moreover, the comfort goals can be reached with thinner insulation on the walls, than suggested by the "Passivhaus" standard, and using the traditional building technologies normally applied in Southern Europe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of proportional of open space to semi-open space in better use of climatic conditions in houses in coastal and foothill areas of East Gilan

Having a mild and humid climate, Gilan province is closer to the comfort zone than other regions of Iran. In addition, the use of radiation, wind, precipitation and humidity components in the spatial organization of native houses has led to the formation of a semi-open space next to the closed space. In general, the placement of spaces in this climate is such that there is no clear border betwe...

متن کامل

Comparative study of the impact of heat transfer coefficient on the comfort conditions in the interior spaces of Iranian traditional houses (warm and dry climate of Yazd and cold and mountainous of Tabriz)

Paper undertakes software based numerical simulations in two different traditional houses in cold-dry climate of Tabriz and hot-arid climate of Yazd, The Eco Test software chosen for BIM simulations. Case study on real houses instead of hypothetical models can give more tangible results and choosing traditional houses can provide a good opportunity to compare both physical and thermal condition...

متن کامل

Analysing the Climatic Impact of Central Courtyards in Traditional Houses of Tabriz

As an inseparable organ, courtyards have influenced the history of architecture with their presence in the context of constructed sites and in a wider sense (architecture), it has provided permissive answers to numerous aspects of climatic, cultural and security demands of the residents. Discovering different aspects of environmental and climatic function in the central courtyard of the traditi...

متن کامل

Impact of Airflow on Moderating Thermal Conditions in Vernacular Houses; Case Study: Bandar-e Lengeh Houses in Hot and Humid Climate of Iran

As an example of extreme hot humid climate, the southern marginal rim of Iran is a perfect candidate for studying climatic patterns. Attention to climatic components in housing design process within this area is therefore essential. Benefitting from the airflow and avoiding heat and radiation are among the most effective approaches towards moderating heat conditions in hot and humid areas. ...

متن کامل

Toward the design of zero energy buildings (ZEB) in Iran: Climatic study

In this research, a combination of passive and active methods is used to design a nearly zero energy building in four major climatic regions of Iran, including cold, mild, dry-warm, and wet-warm ones. The annual energy consumption analysis is performed using DesignBuilder® software. The passive strategies include Trombe Wall, blue roof, and thermochromic windows, and the active methods are usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016