High incidence of intramural thrombus after overlapping paclitaxel-eluting stent implantation: angioscopic and histopathologic analysis in porcine coronary arteries.

نویسندگان

  • Toshiro Shinke
  • Jinsheng Li
  • Jack P Chen
  • Lakshmana Pendyala
  • Traci Goodchild
  • Refat Jabara
  • Sarah Geva
  • Takafumi Ueno
  • Nicolas Chronos
  • Keith Robinson
  • Dongming Hou
چکیده

BACKGROUND Systematic analysis of in vivo angioscopy and postmortem histopathology for paclitaxel-eluting stents (PES) has not been previously reported. We assessed 1-month angioscopic and histopathologic sequelae of overlapping PES in pig coronary arteries. METHODS AND RESULTS Overlapping PES and bare-metal stents (BMS; n=9, one pair per pig) were implanted, and animals were euthanized at 1 month. Late lumen loss was reduced in PES compared with BMS (0.46+/-0.63 mm versus 1.30+/-0.50 mm; P=0.01). Angioscopically, PES stent struts were clearly visible and accompanied by substantial red material indicating mural thrombi. In contrast, stent struts and mural thrombi were barely visible in BMS (P<0.001 versus PES). Macroscopically, mural thrombi were abundant but distributed irregularly throughout the PES, with greater concentration in overlapping segments. Only occasional mural thrombi were noted for BMS. Microscopically, neointima of BMS was fibrocellular and mature, whereas only a thin layer of immature neointima was seen in PES. Neointimal thickness was less in PES than BMS (0.11+/-0.07 mm versus 0.33+/-0.12 mm; P=0.018). Additionally, extensive para-strut and intramural thrombi, red blood cell debris, and minute luminal thrombi were observed in PES. Despite normal angioscopic appearance of both proximal and distal nonstented reference segments, endothelium-dependent relaxation to substance P was notably diminished (PES, 0+/-7% versus BMS, 10+/-6%; P=0.007), whereas nitroglycerin response was preserved (PES, 9+/-5% versus BMS, 12+/-7%; P=0.34). CONCLUSIONS In the porcine coronary model, overlapping PES is associated with marked intramural thrombi, which was accurately detected on angioscopy at 1 month. Moreover, despite normal luminal angioscopic appearance, adjacent nonstented reference segments demonstrated impaired endothelium-dependent vasoreactivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High incidence of thrombus formation at 18 months after paclitaxel-eluting stent implantation: angioscopic comparison with sirolimus-eluting stent.

BACKGROUND Difference of neointimal formational pattern and incidence of thrombus formation between sirolimus-eluting stent (SES) and paclitaxel-eluting stent (PES) at 18 months after stent implantation has not previously been reported. METHODS We retrospectively enrolled 35 event-free patients who received SES (15 patients, 18 stents) or PES (20 patients, 23 stents) implantation with 18-mont...

متن کامل

Angioscopic assessment of early phase arterial repair after paclitaxel-coated nitinol drug-eluting stent implantation in the superficial femoral artery.

BACKGROUND Although durable clinical outcomes have been reported, arterial repair after paclitaxel-coated nitinol drug-eluting stent (Zilver PTX) implantation in the superficial femoral artery (SFA) remains unclear. METHODS AND RESULTS Angioscopic evaluation was performed in SFA intra-stent surfaces 80±29 (range, 49-135) days or 84±18 (range, 52-112) days following Zilver PTX (20 stents in 10...

متن کامل

Novel biodegradable polymer-coated, paclitaxel-eluting stent inhibits neointimal formation in porcine coronary arteries.

BACKGROUND Biodegradable polymer-coated stents may have positive effects on arterial healing, and reduce the need for prolonged antiplatelet therapy. AIM To assess the vascular effects of the biodegradable polymer proposed as a stent coating, as well as to evaluate inhibition of intimal hyperplasia by Biodegradable Polymer-Coated Paclitaxel-Eluting Stents (BP-PES, LUC-Chopin, Balton) in porci...

متن کامل

Lack of association between large angiographic late loss and low risk of in-stent thrombus: angioscopic comparison between paclitaxel- and sirolimus-eluting stents.

BACKGROUND It recently has been hypothesized that a larger late loss may have a protective role against stent thrombosis. The relationship between angiographic late loss and the presence of thrombus based on angioscopic findings within paclitaxel-eluting stents (PES) and sirolimus-eluting stents (SES) was investigated in this study. METHODS AND RESULTS Prospective 6-month follow-up angiograph...

متن کامل

Histopathological Analysis of Drug Eluting Stents in Porcine Coronary Restenosis Model

The aim of this study was to compare the two types of drug-eluting stents with histological analysis in porcine coronary restenosis model. Pigs were randomized into two groups in which the coronary arteries (12 pigs, 12 coronaries in each group) had either biolimus-eluting stent with biodegradable polymer (BPS) or sirolimus-eluting stent with durable polymer (DPS). Radiological analysis was per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 1 1  شماره 

صفحات  -

تاریخ انتشار 2008