3066 consecutive Gamma Nails. 12 years experience at a single centre

نویسندگان

  • Alicja J Bojan
  • Claudia Beimel
  • Andreas Speitling
  • Gilbert Taglang
  • Carl Ekholm
  • Anders Jönsson
چکیده

BACKGROUND Fixation of trochanteric hip fractures using the Gamma Nail has been performed since 1988 and is today well established and wide-spread. However, a number of reports have raised serious concerns about the implant's complication rate. The main focus has been the increased risk of a subsequent femoral shaft fracture and some authors have argued against its use despite other obvious advantages, when this implant is employed. Through access to a uniquely large patient data base available, which is available for analysis of trochanteric fractures; we have been able to evaluate the performance of the Gamma Nail over a twelve year period. METHODS 3066 consecutive patients were treated for trochanteric fractures using Gamma Nails between 1990 and 2002 at the Centre de Traumatologie et de l'Orthopedie (CTO), Strasbourg, France. These patients were retrospectively analysed. Information on epidemiological data, intra- and postoperative complications and patients' outcome was retrieved from patient notes. All available radiographs were assessed by a single reviewer (AJB). RESULTS The results showed a low complication rate with the use of the Gamma Nail. There were 137 (4.5%) intraoperative fracture-related complications. Moreover 189 (6.2%) complications were detected postoperatively and during follow-up. Cut-out of the lag screw from the femoral head was the most frequent mechanical complication (57 patients, 1.85%), whereas a postoperative femoral shaft fracture occurred in 19 patients (0.6%). Other complications, such as infection, delayed healing/non-union, avascular femoral head necrosis and distal locking problems occurred in 113 patients (3.7%). CONCLUSIONS The use of the Gamma Nail in trochanteric hip fractures is a safe method with a low complication rate. In particular, a low rate of femoral shaft fractures was reported. The low complication rate reported in this series can probably be explained by strict adherence to a proper surgical technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Critical factors in cut-out complication after gamma nail treatment of proximal femoral fractures

BACKGROUND The most common mechanical failure in the internal fixation of trochanteric hip fractures is the cut-out of the sliding screw through the femoral head. Several factors that influence this complication have been suggested, but there is no consensus as to the relative importance of each factor. The purpose of this study was to analyse the cut-out complication with respect to the follow...

متن کامل

Management of pediatric femoral shaft fractures with long intramedullary kirshner wires

I ntramedullary titanium elastic nails (TEN) have been used for treatment of the pediatric patients with femoral shaft fractures in the last 15 20 years. They are load bearing devices and are flexible to allow bending. Small incisions are required for introduction of these nails and they are easy to remove. High cost is a disadvantage. However in the developing countries, where cost and afforda...

متن کامل

Surgery for aortic stenosis in severely symptomatic patients older than 80 years: experience in a single UK centre.

OBJECTIVE To ascertain the surgical risk and long term outcome of patients over 80 years old undergoing aortic valve replacement (AVR). DESIGN Consecutive cases with respective case note audit and a telephone questionnaire. SETTING Single UK cardiothoracic surgical centre. PATIENTS 103 (48 male) patients over 80 years old undergoing AVR. The median age was 82 years (80-95 years) and 95 of...

متن کامل

Minimally invasive radionuclide-guided parathyroidectomy using 99mTc-sestamibi in patients with primary hyperparathyroidism: a single-institution experience.

OBJECTIVE To evaluate the efficacy and usefulness of (99m)Tc-sestamibi scintigraphy and gamma probe localization of parathyroid glands in patients with primary hyperparathyroidism and establish radio-guided minimally invasive parathyroidectomy at Hussain Makki Al Jumma Center for Specialized Surgery, Kuwait. SUBJECTS AND METHODS Twelve patients with primary hyperparathyroidism (mean age: 48 +...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010