Intrathecal Pump Exposure to Electromagnetic Interference: A Report of Device Interrogation following Multiple ECT Sessions.

نویسندگان

  • Mark C Bicket
  • George M Hanna
چکیده

BACKGROUND Intrathecal drug delivery systems represent an increasingly common treatment modality for patients with a variety of conditions, including chronic pain and spasticity. Pumps rely on electronic programming to properly control and administer highly concentrated medications. Electromagnetic interference (EMI) is a known exposure that may cause a potential patient safety issue stemming from direct patient injury, pump damage, or changes to pump operation or flow rate. OBJECTIVES The objective of our case report was to describe an approach to evaluating a patient with a pump prior to and following exposure to EMI from electroconvulsive therapy (ECT), as well as to document findings from device interrogations associated with this event. STUDY DESIGN Case report. SETTING Academic university-based pain management center. RESULTS We present the case of a patient with an intrathecal pump who underwent multiple exposures to EMI in the form of 42 ECT sessions. Interrogation of the intrathecal drug delivery system revealed no safety issues following ECT sessions. At no time were error messages, unintentional changes in event logs, unintentional changes in pump settings, or evidence of pump stall or over-infusion noted. CONCLUSION Communication with multiple entities (patient, family, consulting physicians, and device manufacturer) and maintaining vigilance through device interrogation both before and after EMI exposure are appropriate safeguards to mitigate the risk and detect potential adverse events of EMI with intrathecal drug delivery systems. Given the infrequent reports of device exposure to ECT, best practices may be derived from experience with EMI exposure from magnetic resonance imaging (MRI). Although routine EMI exposure to intrathecal drug delivery systems should be avoided, we describe one patient with repeated exposure to ECT without apparent complication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SynchroMed II intrathecal pump memory errors due to repeated magnetic resonance imaging.

Cancer patients with severe refractory pain are often managed with implantable drug delivery systems (IDDS). The only drugs with US Food and Drug Administration approval for intrathecal use are morphine, ziconotide, and baclofen. Other drugs used and mixed include, hydromorphone, bupivacaine, sufentanil, and fentanyl. These patients often undergo magnetic resonance imaging (MRI) for disease-rel...

متن کامل

Effect of Pulse-Modulated GSM-900 MHz Electromagnetic Field on the Electrochemotherapy Efficacy of 4T-1 Cells

Introduction: Electrochemotherapy (ECT) is a cancer treatment modality to permeabilize cell membrane facilitating the non-permeant molecules to gain access to the cytosol of cells. Nevertheless, environmental electromagnetic fields (EMFs) may disturb the efficiency of ECT. The present study aimed to investigate the effect of EMFs 900 MHz pulse-modulated by 217 Hz extremely low-frequency fields ...

متن کامل

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...

متن کامل

Exposure to electromagnetic fields at two call centers in Turkey, 2015

Background: This study aims to evaluate the negative health impacts of exposure to electromagnetic field and to prepare a risk map of two selected call centers. Materials and Methods: Two call centers whose electromagnetic field values were measured by calibrated low high and point frequency measurement device. The measurements were performed by following the EN 50492 Standards. 178 employees ...

متن کامل

Use of Intrathecal Fluorescein in Recurrent Meningitis after Cochlear Implantation-A Case Report

Introduction: Congenital anomalies of the cochlea and labyrinth can be associated with meningitis and varying degrees of hearing loss or deafness. Despite antibiotics, meningitis remains a life threatening complication.   Case Report: We report a case of recurrent meningitis following episodes of otitis media in a cochlear implantee child with bilateral vestibulocochlear malformation, due to f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pain physician

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 2016