Significant Decline in Galactomannan Signal during Storage of Clinical Serum Samples
نویسندگان
چکیده
Galactomannan (GM) is widely used for detection of invasive aspergillosis in high-risk haemato-oncology patients. Recent publications have reported a lack of repeatability of GM detection. The objective of this retrospective study was to assess the repeatability of GM levels during storage of clinical samples. In a GM screening strategy, positive sera were repeat tested as per manufacturer's recommendations. Short-term (ST) storage of samples was at +4 °C while long-term (LT) storage was at -80 °C. Bronchoalveolar (BAL) fluid was also repeating tested after ST storage and LT storage. Wilcoxon Signed Ranks Test was employed to assess the repeatability of GM levels. In a subset of 14 GM positive sera, repeat testing was performed on both the original serum and ethylenediaminetetraacetic acid (EDTA) pre-treated sample. There was a significant reduction in GM signals on repeat testing following ST storage (median GM index: 0.65 vs. 0.19; p < 0.001) and LT storage (median GM index: 0.56 vs. 0.10; p < 0.001) of serum samples. Of samples that were initially GM positive, an average GM index reduction of 50% was seen, with approximately two-thirds becoming GM negative on repeat testing of the same sample. In contrast, GM signal loss was not seen on repeat testing of BAL fluid following ST or LT storage. When GM positive serum samples were repeat tested using EDTA pre-treated serum from the first step of the testing protocol, all samples remained GM positive. In contrast, when the same samples were repeat tested from the original collected serum, 9 samples (64%) became GM negative. The significant reduction in GM signals during ST and LT storage of serum samples has implications for clinical management. Although the reasons for GM decline are unknown, they occur prior to the EDTA pre-treatment stage, indicating that the time from phlebotomy to testing should be minimized. BAL fluid GM index values remain stable.
منابع مشابه
Instability of Aspergillus galactomannan in stored clinical samples.
We read with interest the recent paper by Wheat et al. (1) reporting on the long-term stability of Aspergillus galactomannan in bronchoalveolar lavage fluid (BALF) and serum specimens stored at 20°C. Their findings contrasted with previously published results from Johnson et al. (2), who had observed a significant loss of signal in serum— but not BALF—samples upon long-term storage. We here exp...
متن کاملThe effect of sample storage on the performance and reproducibility of the galactomannan EIA test.
Galactomannan enzyme immune assay (GM EIA) is a nonculture test for detecting invasive aspergillosis (IA) forming a key part of diagnosis and management. Recent reports have questioned the reproducibility of indices after sample storage. To investigate this, 198 serum samples (72 from cases and 126 from controls) and 61 plasma samples (24 from cases and 37 from controls), initially tested betwe...
متن کاملAspergillus meningitis: diagnosis by non-culture-based microbiological methods and management.
The performance of antibody detection, antigen detection, and Aspergillus genus-specific PCR for diagnosing Aspergillus meningitis was investigated with 26 cerebrospinal fluid (CSF) samples obtained from a single patient with proven infection caused by Aspergillus fumigatus. Immunoglobulin G antibodies directed against Aspergillus were not detected by enzyme-linked immunosorbent assay in CSF or...
متن کاملClinical evaluation and reproducibility of the Pastorex Aspergillus antigen latex agglutination test for diagnosing invasive aspergillosis.
AIMS The performance of the Pastorex Aspergillus antigen latex agglutination test for the detection of galactomannan in sera of patients at risk for invasive aspergillosis was evaluated, and the impact of storage on the reproducibility of the antigen titre was tested. METHODS During a one year period, 392 serum samples were obtained from 46 patients at risk for invasive aspergillosis and test...
متن کاملAspergillus galactomannan antigen in the cerebrospinal fluid of bone marrow transplant recipients with probable cerebral aspergillosis.
The Aspergillus galactomannan test was performed on cerebrospinal fluid and serum samples from 5 patients with probable cerebral aspergillosis and from 16 control patients. Cerebrospinal fluid galactomannan levels were significantly higher in aspergillosis patients, and most galactomannan was produced intrathecally. Comparison of serum galactomannan values in pulmonary and cerebral aspergillosi...
متن کامل