Conventional testing methods produce submaximal values of maximum oxygen consumption.
نویسندگان
چکیده
BACKGROUND This study used a novel protocol to test the hypothesis that a plateau in oxygen consumption (VO(2 max)) during incremental exercise testing to exhaustion represents the maximal capacity of the cardiovascular system to transport oxygen. METHODS Twenty-six subjects were randomly divided into two groups matched by their initial VO(2 max). On separate days, the reverse group performed (i) an incremental uphill running test on a treadmill (INC(1)) plus verification test (VER) at a constant workload 1 km h(-1) higher than the last completed stage in INC(1); (ii) a decremental test (DEC) in which speed started as same as the VER but was reduced progressively and (iii) a final incremental test (INC(F)). The control group performed only INC on the same days that the reverse group was tested. RESULTS VO(2 max) remained within 0.6 ml kg(-1) min(-1) across the three trials for the control group (p=0.93) but was 4.4% higher during DEC compared with INC(1) (63.9 ± 3.8 vs 61.2 ± 4.8 ml kg(-1) min(-1), respectively, p=0.004) in the reverse group, even though speed at VO(2 max) was lower (14.3 ± 1.1 vs 16.2 ± 0.7 km h(-1) for DEC and INC(1), respectively, p=0.0001). VO(2 max) remained significantly higher during INC(F) (63.6 ± 3.68 ml kg(-1) min(-1), p=0.01), despite an unchanged exercise time between INC(1) and INC(F). CONCLUSION These findings go against the concept that a plateau in oxygen consumption measured during the classically described INC and VER represents a systemic limitation to oxygen use. The reasons for a higher VO(2) during INC(F) following the DEC test are unclear.
منابع مشابه
Exogenous Ketone Supplement Ingestion And Submaximal Exercise Response in Trained, Male Cyclists: A Randomised, Double-blind Study
Background. The acute ingestion of ketone body supplements can improve exercise responses such as oxygen consumption and blood lactate. Additionally, ketone body supplements show increases in circulating βhb concentration, matching those of someone in a state of nutritional ketosis. Studies testing ketone body supplements have reported different results in exercise response and varying gastroin...
متن کاملOxygen deficit during exercise testing in heart failure. Relation to submaximal exercise tolerance.
Measurements of oxygen deficit during submaximal exercise were correlated with the anaerobic threshold (as measured by gas exchange analysis), peak work rate on a ramp protocol, and the ability to perform constant work rate exercise in 10 male patients with New York Heart Association class 2 congestive heart failure and 12 age- and gender-matched normal controls. All subjects performed a maxima...
متن کاملEffects of Chainring Type (Circular vs. Rotor Q-Ring) on 1km Time Trial Performance Over Six Weeks in Competitive Cyclists and Triathletes
The purpose of this study was to examine the effects of chainring type (circular vs. the noncircular Rotor Q-Ring) on performance during a 1km time trial and physiological responses over a six week period. Eight competitive male cyclists and triathletes were pre-tested using the original circular chainring. Graded submaximal exercise tests were followed by the 1km time trial with subjects using...
متن کاملReproducibility of cardiorespiratory measurements during submaximal and maximal running in children.
With the increased use of oxygen consumption measurements in clinical and sporting studies, measurement variability has become more important to both the paediatric clinician and the sports scientist. In this study we assessed the reproducibility of cardiorespiratory measurements during submaximal and maximal running in children. Ten healthy, physically active boys (mean(s.d.) age 10.7(0.71) ye...
متن کاملValidation of 2 Submaximal Cardiorespiratory Fitness Tests in Patients With Breast Cancer Undergoing Chemotherapy
Patients with breast cancer have an impaired cardiorespiratory fitness, in part, due to the toxic effects of anticancer therapy. Physical exercise as a means of rehabilitation for patients with cancer is an emerging area of research and treatment, emphasizing the need for accurate and feasible physical capacity measurements. The purpose of this study was to evaluate the validity of peak oxygen ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British journal of sports medicine
دوره 46 1 شماره
صفحات -
تاریخ انتشار 2012