Intra- and interlaboratory sources of imprecision in drug measurements by different techniques.

نویسندگان

  • L M Tsanaclis
  • J F Wilson
چکیده

We compared the intra- and interlaboratory precision of seven techniques used to measure eight antiepileptic drugs, digoxin, and theophylline by using data from the international Healthcontrol external quality-assessment scheme. Scheme participants were supplied blind with 6 or 12 sets of duplicate lyophilized serum samples. Each set contained different drug concentrations, and duplicates were analyzed separately, 1 to 6 months apart. The intra- and interlaboratory components of assay variance were isolated and compared by Bartlett's test for homogeneity of variance. Fluorescence polarization immunoassay (Abbott) showed the best overall intra- and interlaboratory performance for a range of analytes. The largest intralaboratory errors were produced by techniques using the Syva EMIT assays. Our analysis of the data shows that for most analyte/technique combinations, intralaboratory sources of variation were more important than interlaboratory sources. Gains in assay precision will therefore result from attention to internal laboratory procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Primary standardization of assays for anticonvulsant drugs: comparison of accuracy and precision.

BACKGROUND The accuracy and precision of methods for the measurement of the anticonvulsants phenytoin, phenobarbital, primidone, carbamazepine, ethosuximide, and valproate in human serum were assessed in 297 laboratories that were participants in the United Kingdom National External Quality Assessment Scheme (UKNEQAS). METHODS We distributed lyophilized, serum-based materials containing low, ...

متن کامل

Establishment and validation of analytical reference panels for the standardization of quantitative BCR-ABL1 measurements on the international scale.

BACKGROUND Current guidelines for managing Philadelphia-positive chronic myeloid leukemia include monitoring the expression of the BCR-ABL1 (breakpoint cluster region/c-abl oncogene 1, non-receptor tyrosine kinase) fusion gene by quantitative reverse-transcription PCR (RT-qPCR). Our goal was to establish and validate reference panels to mitigate the interlaboratory imprecision of quantitative B...

متن کامل

Therapeutic Drug Monitoring of Sirolimus,Correlation With Laboratory Parameters In Transplant Patients

Sirolimus is a potent immunosuppressive agent administered as prophylactic agent to prevent rejection after organ transplantation. Sirolimus must be used within a narrow therapeutic window. Due to inter- and intra-variability, sirolimus blood concentrations may be affected, therefore, there is no possibility of predicting the sirolimus blood concentrations based on the dose patients received. T...

متن کامل

Interlaboratory agreement of insulin-like growth factor 1 concentrations measured by mass spectrometry.

BACKGROUND Insulin-like growth factor 1 (IGF-1)(7) is a key mediator of growth hormone (GH) action and a well-characterized biomarker of GH abuse. Current immunoassays for IGF-1 suffer from poor concordance between platforms, which makes comparison of results between laboratories difficult. Although previous work has demonstrated good interlaboratory imprecision of LC-MS/MS methods when plasma ...

متن کامل

Review Article: A review of advantages and disadvantages of different intraoral and extraoral autogenic osseous grafts in the reconstruction of bony defects

Abstract While performing a tooth extraction surgery, removal of implants with incorrect orientation, or sinus lift choosing the best source of graft is always facing a challenge. Various options are available for obtaining grafts to reconstruct the defects. To make the wise choice in each case we should follow these  questions:Is autogenic grafts still the gold standard?  What are the b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 5  شماره 

صفحات  -

تاریخ انتشار 1993