Male-female differences in forearm skin tissue dielectric constant.

نویسندگان

  • Harvey N Mayrovitz
  • Sophia Carson
  • Michelle Luis
چکیده

Tissue dielectric constant (TDC) measurements at 300 MHz via the coaxial line reflection method are useful to evaluate local skin tissue water and its change, but virtually all available data relate to measurements on women. Because TDC values in part depend on skin thickness, we hypothesized that differences in male-female skin may be associated with male-female differences in TDC. To test this hypothesis, we compared TDC values in volar forearm skin of 60 young adult volunteers (30 men, 25.0 +/- 2.5 years, 30 women, 27.4 +/- 6.6 years) in the seated position using a probe with an effective measurement depth of 1.5 mm. Results showed that TDC values (mean +/- SD) for men were significantly greater than for women (33.2 +/- 4.0 versus 29.4 +/- 2.7, P<0.001) constituting an overall difference of about 13%. This finding suggests that when TDC measurements are used in research or clinical studies in which both men and women are included in a common study population, it would be prudent to consider this difference in both experimental design and data interpretation. This is especially true if absolute TDC values are of interest in contrast to changes in TDC values on the same subject subsequent to time passage or secondary to an intervention. Despite greater TDC values measured in men, calculations of the impact of a greater male skin thickness indicate that the greater TDC values of men may or may not reflect a greater relative local skin tissue water in men compared to women.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gender differences in facial skin dielectric constant measured at 300 MHz.

BACKGROUND/PURPOSE Skin tissue dielectric constant (TDC) measurements at 300 MHz provide non-invasive data on free and bound tissue water. TDC-data is available for some body sites, but most is for female forearm. Contrastingly, there are no data on face-skin or comparative data between genders. Our goals were to obtain facial-TDC reference values and determine if TDC-values differ between gend...

متن کامل

Race-related differences in tissue dielectric constant measured noninvasively at 300 MHz in male and female skin at multiple sites and depths.

BACKGROUND/PURPOSE We hypothesized that reported race-related differences in skin properties cause skin and skin-to-fat water differences among races that are measureable by skin tissue dielectric constant (TDC) values that depend strongly on water content. Our first aim was to test this hypothesis. Also, since inter-side TDC ratios are used to assess edema and lymphedema, the second aim was to...

متن کامل

Young adult gender differences in forearm skin-to-fat tissue dielectric constant values measured at 300 MHz.

BACKGROUND/PURPOSE Skin-to-fat tissue dielectric constant (TDC) values depend on measurement depth and gender. Our goal was to assess male-female differences in TDC values associated with differing skin depths. METHODS Bilateral forearm TDC measurements were made on young adult male and females with mean ages from 24.7 to 27.3 years. There were four measurement groups distinguished by the TDC...

متن کامل

Age-related differences in tissue dielectric constant values of female forearm skin measured noninvasively at 300 MHz.

BACKGROUND/PURPOSE We hypothesized that reported age-related shifts in skin water from less-to-more mobile states would result in increased skin tissue dielectric constant (TDC) values as TDC values depend strongly on water content and state. One aim was to test this hypothesis. Further, as skin-to-fat TDC values are used as a tool for edema and lymphedema assessment, a second aim was to establ...

متن کامل

Tissue dielectric constant (TDC) as an index of localized arm skin water: differences between measuring probes and genders.

An easily measured, non-invasive, quantitative estimate of local skin tissue water is useful to assess local lymphedema and its change. One method uses skin tissue dielectric constant (TDC) values that at 300 MHz TDC depend on free and bound water within the measurement volume. In practice such measurements have been done with a research-type multi-probe, but recently a hand-held compact-probe ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical physiology and functional imaging

دوره 30 5  شماره 

صفحات  -

تاریخ انتشار 2010