Irradiation of pacemakers and cardio-defibrillators in patients submitted to radiotherapy: a clinical experience.

نویسندگان

  • Teresa Ferrara
  • Barbara Baiotto
  • Giuseppe Malinverni
  • Nicola Caria
  • Elisabetta Garibaldi
  • Gilberto Barboni
  • Michele Stasi
  • Pietro Gabriele
چکیده

AIMS AND BACKGROUND A prospective analysis was carried out on a group of irradiated patients with pacemakers or implantable cardioverter-defibrillators to identify any relationship between the various types of devices and physical and dosimetric parameters. Cardiac toxicity of the treatment was also investigated. METHODS AND STUDY DESIGN Forty-five irradiated patients, implanted with pacemakers or implantable cardioverter-defibrillators, were prospectively investigated from 1999 to 2007. An analysis of radiation damage to pacemakers, depending on the geometric and dosimetric characteristics of the radiation beams, was carried out. The electric and magnetic fields of linear accelerators (LINACs) were measured to evaluate any interference. The calculation of dose received by pacemakers was evaluated by dose-volume histograms. RESULTS No dysfunction was observed in any pacemaker, nor were the substitution times negatively affected. We did not find problems with the devices due to the interaction with the electromagnetic fields. Dose-volume histograms calculated for patients treated in regions close to devices (head & neck, thorax) showed an average maximum dose equal to 2.5 Gy for the head & neck area and equal to 1.8 Gy for the thoracic area. Acute (3 cases) and late (2 cases) cardiac events were observed only in 5 patients who underwent chemoradiation treatment, but no dysfunction was observed in any pacemaker. CONCLUSIONS Our study confirms the safety of radiotherapy for patients implanted with pacemakers or implantable cardioverter-defibrillators but suggests that chemoradiation represents a probable risk factor for cardiac toxicity. Furthermore, all cardiac events were observed in patients treated in the head and'neck or left thoracic areas. A standardized protocol is advisable in order to improve patient control during the radiotherapy treatment. It is mandatory to calculate the dose received at the pacemaker/heart, even in the case of palliative treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A national audit of current cardiac device policies from radiotherapy centres across the UK.

AIMS The number of patients with cardiac implantable electronic devices (permanent pacemakers and implantable cardioverter defibrillators) undergoing radiotherapy treatment is increasing. The aims of this audit were to establish current UK practice regarding the management of patients with implanted cardiac devices undergoing radiotherapy and to compare this practice with current 'gold standard...

متن کامل

Post-operative radiotherapy of keloids. A 10-years experience of kilovoltage irradiation

Background: Keloids are benign fibrous dermal tumors originating from skin injury after surgery, piercing or others wounds. Materials and Methods: Sixty-two patients with keloids were treated postoperatively using orthovoltage irradiation. The total dose delivered was 12 Gy in three consecutive days, 4Gy per fraction. Treatment started 24 h after surgery. The median follow-up was 44.5 months. R...

متن کامل

COMPLICATIONS OF TREATMENT Radiotherapy to patients with artificial cardiac pacemakers

Background: The in vitro studies show that the modern cardiac pacemakers utilising the complementary metal-oxide semi-conductor (CMOS) circuitry can be adversely affected by therapeutic radiation. However, the published clinical data are sparse regarding the safety of radiotherapy delivery to patients with artificial pacemakers. Despite the potential risk of life threatening complications, ther...

متن کامل

Radiation Therapy to Patients with Cardiac Implanted Electronic Devices

There is an increase of the number of patients with cardiac implantable electronic devices (CIEDs, like pacemakers and cardioverter defibrillators) that require radiotherapy for cancer treatment. Managing such patients has been a great practical and procedural challenge in radiation oncology practice. This editorial will focus on outlining the most important risks of using new techniques of rad...

متن کامل

Use of Apoptotic Biomarkers to Predict Response to Radiotherapy in Breast Cancer Patients

Introduction: To enhance radiation therapy efficiency it is crucial to implement an individual-based treatment. The aim of present study was to identify the mechanism of intrinsic apoptosis pathway on radiosensitivity and normal tissue complications caused by the radiotherapy.   Materials and Methods: radiation-induced apoptosis in periphera...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Tumori

دوره 96 1  شماره 

صفحات  -

تاریخ انتشار 2010