Determination of mycophenolic acid in human plasma by high-performance liquid chromatography.

نویسندگان

  • V Srivatsan
  • A K Dasgupta
  • Prashant Kale
  • Ravi Verma
  • Paresh Joshi
  • Devangi Soni
  • Mahendra Patel
  • Gunjan Soni
  • Jignesh Patel
  • Harshad Modi
چکیده

The development, validation and evaluation of high-performance liquid chromatography (HPLC) method for quantifying mycophenolic acid in human plasma is described. The method involved protein precipitation using acetonitrile, after addition of terazosin as an internal standard. Separation was achieved with a reversed-phase C18 column (250 mm x 4.6 mm) employing UV detection at 215 nm. The mobile phase consisted of 0.02 M potassium dihydrogenphosphate solution adjusted to pH 6.9 with 2 M potassium hydroxide solution-acetonitrile (80:20 (v/v)) at a flow rate of 1.5 ml/min. The total run time was 21.0 min. The assay was linear from 0.2 to 25 microg/ml with goodness of fit (r2) greater than 0.99 observed with three precision and accuracy batches during validation. The observed mean recoveries were 89.3 and 98.0% for drug and internal standard, respectively. The applicability of this method to pharmacokinetic studies was established after successful application during a 34-subject bioavailability study. The method was found to be precise, accurate and specific during the study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trace Determination of Duloxetine in Human Plasma by a Novel Ionic Liquid-Based Ultrasound-Assisted In Situ Solvent Formation Microextraction and High-Performance Liquid Chromatography

For the first time, a novel and efficient ionic liquid-based ultrasound-assisted in-situ solvent formation microextraction (IL-UA-ISFME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) has been successfully developed for the determination of duloxetine (DLX) in human plasma. Herein, an environmentally-friendly hydrophobic ionic liquid (1-butyl-3-methylimidaz...

متن کامل

High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...

متن کامل

High-Performance Liquid Chromatographic Determination of Rivastig-mine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using ...

متن کامل

Vortex-Assisted Inverted Dispersive Liquid-Liquid Microextraction of Naproxen from Human Plasma and Its Determination by High-Performance Liquid Chromatography

Extraction and determination of naproxen from human plasma were performed using Vortex-Assisted Inverted Dispersive Liquid-Liquid MicroExtraction (VA−IDLLME) and High-Performance Liquid Chromatography (HPLC). The parameters affecting extraction recovery such as type and volume of extraction and disperser solvents, pH of sample solution, stirring rate, extraction time and salt addition were ...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Lighter than Water Dispersive Liquid-liquid Microextraction Coupled with High Performance Liquid Chromatography for Determination of Cholecalciferol and Calcifediol from Plasma

In this study, a dispersive liquid–liquid microextraction method using an extraction solvent lighter than water has been developed for the extraction and preconcentration of cholecalciferol and calcifediol from plasma samples followed by high performance liquid chromatography determination. Initially, acetonitrile and sodium chloride (NaCl) are added into the plasma as an extraction solvent and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1031 1-2  شماره 

صفحات  -

تاریخ انتشار 2004