Biodegradable 3D-Porous Collagen Matrix (Ologen) Compared with Mitomycin C for Treatment of Primary Open-Angle Glaucoma: Results at 5 Years

نویسندگان

  • Fei Yuan
  • Lei Li
  • Xiuping Chen
  • Xiang Yan
  • Liyang Wang
چکیده

Purpose. To evaluate the effectiveness and safety of the Ologen as an aid for trabeculectomy performed for primary open-angle glaucoma compared with mitomycin C. Methods. In this prospective, randomized, parallel assignment, comparative study, 31 eyes of 21 primary open-angle glaucoma patients were allocated for trabeculectomy with the Ologen implant; another 32 eyes of 23 patients were treated with trabeculectomy augmented with mitomycin C. The patients were followed up for 5 years and evaluated for intraocular pressure, rate of success, status of the bleb, and adverse events. Result. The mean postoperative intraocular pressure was statistically different at 3 m, 6 m, 1 y, 3 y, and 5 y follow-up. The rates of both complete success (P = 0.017) and overall success (P = 0.031) in the Ologen group were significantly higher than those in the mitomycin C group. The difference of the bleb extent and vascularity was statistically significant in both groups. There was no significant difference in postoperative complication. Conclusions. Ologen provides higher rates of surgical success compared with mitomycin C for patients with primary open-angle glaucoma undergoing trabeculectomy. It may be a new, safe, simple, and effective therapeutic approach for treating primary open-angle glaucoma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trabeculectomy with combined use of subconjunctival collagen implant and low-dose mitomycin C.

PURPOSE To evaluate outcomes of trabeculectomy with use of a subconjunctival biodegradable collagen implant (Ologen) combined with mitomycin C (MMC). METHODS This retrospective study included 33 eyes of 24 patients with primary open-angle glaucoma who underwent fornix-based trabeculectomy with subconjunctival Ologen implant and MMC (0.1 mg/mL×1 min) between October 2008 and April 2010. Data p...

متن کامل

New Glaucoma

EUROTIMES | Volume 17 | Issue 11 A new collagen matrix implant could provide a viable alternative to traditional antimetabolites such as mitomycin C (MMC) and 5-fluorouracil in glaucoma filtration procedures, according to Steven R Sarkisian Jr MD. “Initial results with the Ologen Collagen Matrix Implant (Optous) are very promising indeed and offers the potential for safer and effective glaucoma...

متن کامل

A Comparative Study: The Use of Collagen Implant versus Mitomycin-C in Combined Trabeculotomy and Trabeculectomy for Treatment of Primary Congenital Glaucoma

PURPOSE To compare Ologen implant versus mitomycin-C (MMC) in combined trabeculotomy and trabeculectomy as a treatment of primary congenital glaucoma. SETTING Sohag University Hospital, Egypt. DESIGN A prospective comparative study. METHODS Thirty-four eyes of twenty-one patients with primary congenital glaucoma were included in this study. All patients were subjected to preoperative eval...

متن کامل

High definition tomography to evaluate filtering bleb with biodegradable collagen implant in patients with high myopia

METHODS: A retrospective descriptive study of 10 patients (10 eyes) diagnosed with chronic open-angle glaucoma and high myopia. Patients underwent trabeculectomy with Ologen® implant, without mitomycin, with follow-up at one, three, six and nine months. Follow-up assessment included refraction, intraocular pressure (IOP), presence of complications, and examination of the bleb and implant using ...

متن کامل

Biodegradable Collagen Implants in Trabeculectomy.

Subconjunctival and subscleral fibrosis are the major causes of failure of filtering surgery. Antiproliferative agents have been successfully used to improve the long-term success of this surgery. Recent advancement in the field of glaucoma surgery has been the use of bioengineered, biodegradable, porous collagen-glycosaminoglycan matrix implant in the subconjunctival and/or subscleral space to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015