Temporary caval stenting improves venous drainage during cardiopulmonary bypass.

نویسندگان

  • Ludwig K von Segesser
  • Giuseppe Siniscalchi
  • Kwang Kang
  • Olaf Maunz
  • Judith Horisberger
  • Enrico Ferrari
  • Dominique Delay
  • Piergiorgio Tozzi
چکیده

OBJECTIVES Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed cannula in trans-jugular fashion. Maximal blood flows were assessed for 20, 25 and 30 mmHg of driving pressure with a motorized table height adjustment system. In addition, the inferior caval diameters (just above its bifurcation) were measured in real time with intra-vascular ultrasound (IVUS). RESULTS Venous drainage (flow in l/min) at 20 mmHg, 25 mmHg, and 30 mmHg drainage load was 3.5+/-0.5, 3.7+/-0.7 and 4.0+/-0.6 for the 28F standard vs. 4.1+/-0.7, 4.0+/-1.3 and 3.9+/-1.1 for the 36F smart 43 cm, vs. 5.0+/-0.7, 5.3+/-1.3 and 5.4+/-1.4 for the 36F smart 53 cm, vs. 5.2+/-0.5*, 5.6+/-1.1* and 5.8+/-1.0* for the 36F smart 63 cm. The inferior vena caval diameters at 30 mmHg were 13.5+/-4.8 mm for 28F standard, 11.1+/-3.6 for 36F smart 43 cm, 11.3+/-3.2 for 36F 53 cm, and 17.0+/-0.1* for 36F 63 cm (*P<0.05 for 28F standard vs. 36F smart 63 cm long) CONCLUSIONS The 43 cm self-expanding 36F smartcanula outperforms the 28F standard wire armed cannula at low drainage pressures and without augmentation. Temporary caval stenting with long self-expanding venous cannulas provides even better drainage (+51%).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Caval collapse during cardiopulmonary bypass: a reproducible bench model.

OBJECTIVES During open heart surgery, so-called atrial chatter, a phenomenon due to right atria and/or caval collapse, is frequently observed. Collapse of the cava axis during cardiopulmonary bypass (CPB) limits venous drainage and may result downstream in reduced pump flow on (lack of volume) and upstream in increased after-load (stagnation), which in turn may both result in reduced or even in...

متن کامل

Establishment of total cavopulmonary connection without use of cardiopulmonary bypass.

OBJECTIVE To minimize deleterious postoperative influences of cardiopulmonary bypass on the pulmonary circulation immediately after the Fontan type procedure, total cavopulmonary connection was achieved without use of cardiopulmonary bypass. METHODS Since April 1996, 15 patients including five patients with visceral heterotaxy, in whom no intracardiac procedure was needed, have undergone this...

متن کامل

Diagnosis of inadvertent cannulation of the azygos vein during cardiopulmonary bypass.

Cardiac surgery with cardiopulmonary bypass demands diligence and attention to detail to prevent neurologic injury. Arterial and venous cannulae are used to facilitate cardiopulmonary bypass. The assessment of adequate decompression of the venous circulation is an essential duty of the cardiac surgical team. Modalities for the assessment of adequate regional venous drainage are limited, however...

متن کامل

Placement of a modified cannula in the innominate vein for sufficient drainage during the bidirectional Glenn shunt procedure without cardiopulmonary bypass

During the bidirectional Glenn shunt procedure in small infants, the standard right-angle venous cannula is frequently placed in the innominate vein for establishing the temporary veno-atrial bypass without cardiopulmonary bypass, but it should be small enough to allow flow to pass around it from the internal jugular vein opposite to the side the cannula is directed. Small cannula may induce th...

متن کامل

Venous cannula performance assessment in a realistic caval tree model.

OBJECTIVES A new caval tree system was designed for realistic in vitro simulation. The objective of our study was to assess cannula performance for virtually wall-less versus standard percutaneous thin-walled venous cannulas in a setting of venous collapse in case of negative pressure. METHODS For a collapsible caval model, a very flexible plastic material was selected, and a model with nine ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 2008