Feasibility of high temporal resolution compressed sensing based DCE-MRI
نویسندگان
چکیده
the average approach and the ME/MC approach. The arrow shows the region where the motion artifact is severer. Fig. 1 Uptake curves reconstructed by RICS with the ME/MC approaches. (a) A representative image showing the tumor and control area (indicated by the black squares) from which uptake curves were calculated. Each of these two areas contained 900 pixels. (b) and (c) The “true” uptake curves (solid line), uptake curves reconstructed by RICS with the average approach (dashed line), and the absolute difference between them (dot-dashed line) from the tumor and control area, respectively. Feasibility of high temporal resolution compressed sensing based DCE-MRI
منابع مشابه
High-resolution whole-brain dynamic contrast-enhanced MRI using compressed sensing
Dynamic contrast-enhanced (DCE) MRI is a powerful tool that maps the spatial distribution of vascular parameters in the brain, including blood-brain-barrier (BBB) permeability, interstitial transit times, and interstitial volume. DCE-MRI is widely used to assess BBB leakage in brain tumors and multiple sclerosis lesions, and it has potential applications in Alzheimer’s dementia, vascular cognit...
متن کاملHigh spatial and temporal resolution black-blood dynamic contrast-enhanced carotid artery wall MRI using compressed sensing
Background Dynamic gadolinium contrast-enhanced (DCE) vessel wall imaging has been used to quantitatively assess the inflammatory status of carotid plaques[1]. However, several limitations of current techniques that may potentially compromise quantitative accuracy include: a) vessel wall blurring during high-spatial-resolution imaging due to arterial pulsation; b) inadequate separation between ...
متن کاملThree-Dimensional Compressed Sensing for Dynamic MRI
Introduction: Dynamic contrast enhanced (DCE) magnetic resonance imaging (MRI) is a valuable tool used in a number of clinical applications. However, imaging of time-varying objects is a challenging task when both high spatial resolution and high temporal resolution is desired. It has been demonstrated that radial imaging techniques can yield increased temporal resolution without sacrificing sp...
متن کاملInfluence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast.
BACKGROUND To evaluate the influence of temporal sparsity regularization and radial undersampling on compressed sensing reconstruction of dynamic contrast-enhanced (DCE) MRI, using the iterative Golden-angle RAdial Sparse Parallel (iGRASP) MRI technique in the setting of breast cancer evaluation. METHODS DCE-MRI examinations of the breast (n = 7) were conducted using iGRASP at 3 Tesla. Images...
متن کاملQuantitative Evaluation of Temporal Regularizers in Compressed Sensing Dynamic Contrast Enhanced MRI of the Breast
PURPOSE Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is used in cancer imaging to probe tumor vascular properties. Compressed sensing (CS) theory makes it possible to recover MR images from randomly undersampled k-space data using nonlinear recovery schemes. The purpose of this paper is to quantitatively evaluate common temporal sparsity-promoting regularizers for CS DCE-MRI o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010