Microbubble detection following hyperbaric chamber dives using dual-frequency ultrasound.

نویسندگان

  • J G Swan
  • B D Bollinger
  • T G Donoghue
  • J C Wilbur
  • S D Phillips
  • D L Alvarenga
  • D A Knaus
  • P J Magari
  • J C Buckey
چکیده

Venous gas emboli (VGE) can be readily detected in the bloodstream using existing ultrasound methods. No method currently exists to detect decompression-induced microbubbles in tissue. We hypothesized that dual-frequency ultrasound (DFU) could detect these microbubbles. With DFU, microbubbles are driven with two frequencies: a lower "pump" (set to the resonant frequency of the desired bubble size) and a higher "image" frequency. A bubble of the resonant size emits the sum and difference of the two transmitted frequencies. For this study we used a pump frequency of 2.25 MHz and an image frequency of 5.0 MHz, which detects bubbles of roughly 1-10 μm in diameter in a water tank. Four anesthetized swine were pressurized at 4.5 ATA for 2 h and decompressed over 5 min, inducing moderate to very severe VGE scores. Four sites on the thigh of each swine were monitored with DFU before and after the dives. A single mock dive was also performed. The number of sites returning signals consistent with microbubbles increased dramatically after the chamber dive (P < 0.01), but did not change with the mock dive. The increase in DFU signal after the chamber dive was sustained and present at multiple sites in multiple swine. This research shows for the first time that decompression-induced tissue microbubbles can be detected using DFU and that DFU could be used to monitor decompression-induced microbubbles at multiple sites on the body. Additionally, DFU could be used to track the time course of microbubble formation and growth during decompression stress.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Observation of increased venous gas emboli after wet dives compared to dry dives.

INTRODUCTION Testing of decompression procedures has been performed both in the dry and during immersion, assuming that the results can be directly compared. To test this, the aim of the present paper was to compare the number of venous gas bubbles observed following a short, deep and a shallow, long air dive performed dry in a hyperbaric chamber and following actual dives in open water. METH...

متن کامل

Ocular tear film bubble formation after breath-hold diving.

Bubbles in the ocular tear film have been observed following both dry-chamber, simulated compressed air dives and in-water, recreational compressed air dives. The current paper reports on the formation of tear film bubbles in a breath-hold diver following repeated, extended breath-hold excursions to a maximum depth of -28.5 m. It is believed that this is the first time that ocular tear film bub...

متن کامل

Experimental trials to assess the risks of decompression sickness in flying after diving.

We conducted experimental trials of flying after diving using profiles near the no-decompression exposure limits for recreational diving. The objective was to determine the dependence of DCS occurrence during or after flight on the length of the preflight surface intervals (PFSI). One to three dives were conducted during a single day with dry, resting subjects in a hyperbaric chamber at depths ...

متن کامل

Dual-Frequency Piezoelectric Transducers for Contrast Enhanced Ultrasound Imaging

For many years, ultrasound has provided clinicians with an affordable and effective imaging tool for applications ranging from cardiology to obstetrics. Development of microbubble contrast agents over the past several decades has enabled ultrasound to distinguish between blood flow and surrounding tissue. Current clinical practices using microbubble contrast agents rely heavily on user training...

متن کامل

Determination of postexcitation thresholds for single ultrasound contrast agent microbubbles using double passive cavitation detection.

This work presents experimental responses of single ultrasound contrast agents to short, large amplitude pulses, characterized using double passive cavitation detection. In this technique, two matched, focused receive transducers were aligned orthogonally to capture the acoustic response of a microbubble from within the overlapping confocal region. The microbubbles were categorized according to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 111 5  شماره 

صفحات  -

تاریخ انتشار 2011