Rapid, single-step most-probable-number method for enumerating fecal coliforms in effluents from sewage treatment plants.

نویسندگان

  • E F Munoz
  • M P Silverman
چکیده

A single-step most-probable-number method for enumerating fecal coliforms in sewage treatment plant effluents is described. The method requires the use of only one lactose-based medium and a single incubation temperature of 44.5 degrees C, and it can be completed in 18 h or less, as compared with up to 72 h for the standard most-probable-number method. The appearance of growth is the sole criterion used for designating positives, which can be determined either by increases in the electrical impedance ratio of inoculated medium, as compared to an uninoculated control using a Bactometer model 32, or by visual examination of inoculated medium for turbidity. In trials with 53 samples of unchlorinated sewage treatment plant effluent, fecal coliform counts by the single-step most-probable-number method, throughout a range of less than 10 to almost 10(7) fecal coliforms per 100 ml of effluent, were in excellent agreement with counts abtained by the standard most-probable-number procedure. Similar agreement was obtained in comparative trials with 31 chlorinated effluent samples from two sewage treatment plants. Overall, 87% of 452 positives were confirmed as containing fecal coliforms. The applicability of the single-step most-probable-number method to automated sewage treatment plant operations is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Membrane filter method for recovery of fecal coliforms in chlorinated sewage effluents.

The standard one-step M-FC broth-membrane-filter procedure for recovery of fecal coliforms from chlorinated sewage effluents is much less effective than the multiple-tube (most-probable-number) technique. A two-step membrane-filter method, using a pre-enrichment technique with phenol red lactose broth and incubation at 35 degrees C for 4 h, followether 18+/-2 h, enhanced fecal coliform recovery...

متن کامل

Evaluation of Methods for Detecting Coliforms and Fecal Streptococci in Chlorinated Sewage Effluents

Total coliform (TC), fecal coliform (FC), and fecal streptococcus (FS) recoveries in chlorinated secondary sewage effluents were investigated by the membrane filter (MF) and multiple-tube (most probable number, MPN) methods. The LES two-step MF method was found to be comparable to the MPN procedure for determining TC. The TC detection was 1.5 times greater by the LES two-step technique than tha...

متن کامل

Comparison of methods of enumerating coliforms after UV disinfection.

In view of the differences that have been found between the most-probable-number and membrane filtration methods for the recovery of coliforms from chlorinated samples, the survival of total and fecal coliforms in UV-irradiated effluent samples, as tested by the most-probable-number and standard single-step membrane filtration methods, was compared. There were no significant differences in the ...

متن کامل

Automated electrical impedance technique for rapid enumeration of fecal coliforms in effluents from sewage treatment plants.

Fecal coliforms growing in a selective lactose-based broth medium at 44.5 degrees C generate a change in the electrical impedance of the culture relative to a sterile control when populations reach 10(6) to 10(7) per ml. The ratio of these changes was measured automatically, and the data were processed by computer. A linear relation was found between the log10 of the number of fecal coliforms i...

متن کامل

Membrane filter technique for the quantification of stressed fecal coliforms in the aquatic environment.

A two-layer membrane filtration (MF) medium (injury-mitigating MF [IM-MF]) and a procedure for the enumeration of injured fecal coliforms are described. These procedures included the addition of glycerol and acetate plus reducing agents to both layers of a two-layer medium and rinsing of the filter with a rich resuscitation medium. Some changes in incubation time and temperatures were used. Thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 37 3  شماره 

صفحات  -

تاریخ انتشار 1979